Message | Meaning | How to solve |
| to the factory adjustment. |
|
E__4 | Check sum of the labelling data is | All labelling parameter have to be |
| wrong. Labelling Parameters are | adjusted again |
| set to the factory adjustment. |
|
E__5 | 10V supply voltage for label | Short circuit in label sensor or cable. |
| sensor low. | Voltage regulator U14 is damaged. |
E__6 | 24V Voltage low | Short circuit on an output. Total load too |
|
| high i.e. max is 3A for all outputs. |
|
| Voltage regulator U1 is damaged. |
|
| Change main board. |
E__7 | Material initialization failed | Check if the label web is threaded |
|
| through the label sensor |
E__8 | Error stepper motor driver | The stepper motor control has detected |
|
| an error. The fault is indicated by the |
|
| LED’s on the driver. |
E__9 | 10V supply for label sensor too | Voltage regulator U14 damaged |
| high |
|
E__10 | Missing label on product | One or several product could not be |
|
| labelled. Distance between products too |
|
| close. Increase speed of printer. |
___0 | Process error (Divide overflow) | Hardware failure external noise. EPROM |
|
| damaged. Turn off power and on again. |
|
| Change EPROM or main board |
___1 | Illegal interrupt (processing error) | Hardware failure external noise. EPROM |
|
| damaged. Turn off power and on again. |
|
| Change EPROM or main board |
___2 | Illegal bank interrupt (processing | Hardware failure external noise. EPROM |
| error) | damaged. Turn off power and on again. |
|
| Change EPROM or main board |
INTO | Illegal interrupt INTP0 (processing | Hardware failure external noise. EPROM |
| error) | damaged. Turn off power and on again. |
|
| Change EPROM or main board. |
Release 11/05 | Page 72 | Errors and warnings |