8.2.3Signals for the EP applicator

For controlling the applicator the signals air stream, cylinder valve and blow on are necessary. After a product signal has occurred the labelling cylinder valve is switched active after the delay STAD. However if at this time the applicator is not in the home position then error message E__2 is generated. After the delay time APT1 the blow on valve is switched active for the time APT2.

When APT2 is completed both the labelling cylinder valve and the blow on valve signals are switched inactive. If the control does not read the home position in the time given - 3* (APT1+ APT2) - than the error message E__2 is generated.

Productstart

 

 

Homeswitch

 

 

Cylinder valve

STAD

APT1

 

 

STAD

1

STAD

2

3

STAD

Blowon valve

APT2

APT1

 

 

4 * (APT1 + APT2)

Dispense label

APT3

 

 

+ Airstream valve

 

 

 

 

 

1Missing Label: Labeller not ready for dispense

2Error: Homeposition not detected

3Error: Applicator not in homeposition

Figure 12 Timing EP applicator