Axis Communications manual Axis 540/640 User’s Manual

Models: 540/640

1 119
Download 119 pages 38.04 Kb
Page 96
Image 96

Appendix A: The Test Button

Factory Default Should you wish to reset the AXIS 540/640 to the factory default Settings settings, the best way to do this is to use the Test button. This

procedure involves switching the AXIS 540/640 off and on.

1.Remove the power cord to switch off the AXIS 540/640.

2.Press and hold down the Test button. Whilst continuing to press the Test button, simultaneously switch on the AXIS 540/640 by replacing the power cord. Keep the Test button pressed for at least 20 seconds after restoring power until the Network indicator flashes at one second intervals.

3.Release the Test button and wait at least five seconds (five indicator flashes).

4.Press and hold the Test button again for at least five seconds until the Network indicator remains constantly lit.

The AXIS 540/640 is now reset to factory default settings. Restart the AXIS 540/640 by switching it off and on.

Note: The Node address parameter NODE_ADDR will remain unchanged, but all other parameters are reset. Should you wish to change the Node address, you may do so via the General Property page, using AXIS NetPilot.

96

AXIS 540/640 User’s Manual

Page 96
Image 96
Axis Communications manual Axis 540/640 User’s Manual