www.baldormotion.com

4.2 Motor power input

The DSM requires an unregulated DC power supply. The power supply current will depend upon voltage and load, but will not exceed 2 A (DSMS17 / DSMS23) or 4 A (DSMS34).

Location

Flying leads (red and black), ‘P’ connector

 

 

Input voltage

+12 to +48 VDC (DSMS17)

range

+12 to +75 VDC (DSMS23, DSMS34)

 

 

Voltage ripple

±10%

 

 

Input current

2 A maximum (DSMS17 / DSMS23)

 

4 A maximum (DSMS34)

 

 

The maximum input voltage of the DSM includes motor back EMF, power supply ripple and high line.

CAUTION

A characteristic of all motors is back EMF. Back EMF is a source of current that can push the output of a power supply beyond the maximum operating voltage of the driver. As a result, damage to the stepper driver could occur over a period of time. Care should be taken so that the back EMF does not exceed the maximum input voltage rating of the DSM.

Cable length, wire gauge and power conditioning devices play a major role in the performance of the DSM. The length of the DC power supply cable to a DSM should not exceed 15 m

(50 ft). If cabling of 15 m (50 ft) or longer is required, the additional length may be gained by adding an AC power supply cable (see Figures 6 and 7). Power supply leads to the DSM need to be twisted. If more than one DSM is to be connected to the same power supply, run separate power and ground leads from the supply to each driver.

 

Cable length up to 15 m

From

Shielded

 

DC Supply

Ferrite

 

twisted

sleeve

+24 V

pair

 

0 V

 

 

500 μF

Connect shield to

 

per

earth ground at

 

Amp

supply end only

 

To

Pi type DSM RFI filter

Red

+flying lead

-Black

flying lead

Figure 6 - Power supply connections, cable length less than 15 m

 

 

 

Cable length up to 15 m

 

To

 

 

 

 

 

 

From

Full wave

Pi type

Shielded

Ferrite

Pi type

DSM

AC

bridge

RFI filter

twisted

sleeve

RFI filter

Red

Supply

rectifier

 

pair

 

+

 

 

 

 

 

flying lead

 

 

 

 

 

-

Black

Transformer:

 

500 μF

Connect shield to

 

 

flying lead

 

 

 

 

0 - 28 VAC RMS for

per

earth ground at

 

 

 

48 VDC systems.

Amp

supply end only

 

 

 

20 - 48 VAC RMS for

75 VDC systems

Figure 7 - Power supply connections, cable length more than 15 m

4-2 Input / Output

MN1940

Page 18
Image 18
Baldor MN1940 installation manual Motor power input