www.baldormotion.com

6.1.4 Motor control problems

 

 

 

 

Symptom

Check

 

 

 

 

Controller outputs

Check that the DSM is powered.

 

appears to be

 

 

working, but will not

Check that the logic connections between motor and controller are

 

cause DSM to turn.

correct.

 

 

Confirm that the sense of the enable input is correct to enable the

 

 

motor (section 4.3.1.3).

 

 

 

 

Controller reports

If the controller is expecting a feedback signal but does not receive

 

that the DSM is not

one, it may assume the DSM is not turning. This could cause the

 

moving and drops

controller to report a following error, to disable the DSM, or both.

 

the enable line.

 

 

 

 

6-2 Troubleshooting

MN1940

Page 34
Image 34
Baldor MN1940 installation manual Motor control problems