www.baldormotion.com
4.2.1 Wire sizes
Table 1 describes the wire sizes to provide optimal protection against EMI and RFI. Correct wire size is determined by the current requirement and the cable length. The actual cable type, wire gauge, shield type and filtering devices used are dependent on the customer’s application and system. Always use shielded twisted pairs for AC and DC supply cables. For logic wiring (see section 4.3) AWG22 wire is recommended.
Supply current | Cable length | Cable length |
| Minimum | |
| (meters) | (feet) |
| Wire Gauge | |
|
|
| AWG |
| mm2 |
| 3 | 10 | 20 |
| 0.5 |
|
|
|
|
|
|
| 8 | 25 | 20 |
| 0.5 |
1 A peak |
|
|
|
|
|
15 | 50 | 18 |
| 1.0 | |
|
|
|
|
|
|
| 23 | 75 | 18 |
| 1.0 |
|
|
|
|
|
|
| 30 | 100 | 16 |
| 1.3 |
|
|
|
|
|
|
| 3 | 10 | 20 |
| 0.5 |
|
|
|
|
|
|
| 8 | 25 | 18 |
| 1.0 |
2 A peak |
|
|
|
|
|
15 | 50 | 16 |
| 1.3 | |
|
|
|
|
|
|
| 23 | 75 | 14 |
| 2.0 |
|
|
|
|
|
|
| 30 | 100 | 14 |
| 2.0 |
|
|
|
|
|
|
| 3 | 10 | 18 |
| 1.0 |
|
|
|
|
|
|
| 8 | 25 | 16 |
| 1.3 |
3 A peak |
|
|
|
|
|
15 | 50 | 14 |
| 2.0 | |
|
|
|
|
|
|
| 23 | 75 | 12 |
| 3.3 |
|
|
|
|
|
|
| 30 | 100 | 12 |
| 3.3 |
|
|
|
|
|
|
| 3 | 10 | 18 |
| 1.0 |
|
|
|
|
|
|
| 8 | 25 | 16 |
| 1.3 |
4 A peak |
|
|
|
|
|
15 | 50 | 14 |
| 2.0 | |
|
|
|
|
|
|
| 23 | 75 | 12 |
| 3.3 |
|
|
|
|
|
|
| 30 | 100 | 12 |
| 3.3 |
|
|
|
|
|
|
Table 1 - Power wire ratings
MN1940 | Input / Output |