3 Basic Installation

3.1 Introduction

You should read all the sections in Basic Installation.

It is important that the correct steps are followed when installing the DSM.

This section describes the mechanical installation of the DSM.

3.1.1 Location requirements

Ensure you have read and understood the warnings and cautions in section 1.

The safe operation of this equipment depends upon its use in the appropriate environment. The following points must be considered:

HThe DSM is designed to be mounted indoors, permanently fixed and located.

HThe DSM must be secured by the holes in the faceplate.

Because the DSM consists of two core components, a drive and a motor, attention must be paid to the thermal specifications of both the motor and the electronics. The following maximum temperatures apply to the DSM:

HThe DSM heat sink temperature must not exceed 85 °C (185 °F).

HThe DSM motor temperature must not exceed 100 °C (212 °F).

MN1940

Basic Installation 3-1