8. Web Interface
Information on supported “Established Timings” (most legacy timings, e.g. 720x400@70H z, 88Hz; 800x600@56Hz, 60Hz,
72Hz, 75Hz; ... ; ...)
SupportedStandard Timing Identications (e.g. 1280x1024@60Hz,160 0x1200@60Hz,...)
DetailedTiming Information. The rst detailed timing description is the “Preferred Timing”of the display and u suallythe m ost
importantinformation in the EDID. It describes in full detail the preferred timing: pixel clock, active pixels, active lines, blanking,
sync width, sync offset(horizontal and vertical),...

About auto resolution

Whenthe ClickShare Base Unit display output is put in auto mode, the display output timings will be based on the Preferred Timing
asdes cribedin the meeting room displayor projector EDID.

About manual resolution setup

When resolution is selectedmanually, the timings of this resolution are taken from the information described in the meeting room
displayor projectorEDID. If a custom resolution is entered that is not described in the EDID, the timing is generated by the Base
Unitfollowing the VESA CVT standard with reduced blanking. Thecalculation is based on the ofcial VESA calculation.
8.8 Output ports

Connected ports

When a portis connected with a display, a green LED before the port name lights up.
Image8-12
Outputports

Output port enable-disabled

Anou tputcan beenabled, what means that a video signal can be sent to the display. Or,a port can be disabled what means that
no video signalis sent to the display.
Toenable an output port, check the checkbox next to Enable.

Resolution

Theresolution of the output video signal can be set to the desired value. Select a value which is supported by the connected display.
Toselect a resolution, click on the drop down box next to Resolution and select the desired value.
WhenAuto is selected, the video output signal resolution will be the one that ts best with the connected display and will be based
onthe Preferred Timing as described in the meeting room display or projector EDID.
When Custom is selected, two extra input elds for horizontal and vertical resolution are displayed. The current displayed values
are taken from the information described in the meeting room display or projector EDID. Edit thec urrentvalues with the desired
horizontaland vertical resolution. Ifa custom resolution is entered that is not described in the EDID, the timing is generated by the
BaseUnit following the VESA CVT standard with reduced blanking. Thecalculation is based on the ofcial VESA calculation.
R5900006 CLICKSHARE 04/12/2013 61