Orbiting

Orbiting Speed Toggle (only in MASTER Orbiting)

Highlight 'SPEED : SLOW' with the control stick and press ENTER to set the ORBITING SPEED to Fast.

Highlight 'SPEED : FAST' with the control stick and press ENTER to set the ORBITING SPEED to Slow

ENTER continues to Set up Orbiting

EXIT returns to path selection menu

ADJUST returns to operational mode.

MASTER ORBITING

CHANGE TO MASTER

MODE : ON

 

SPEED : FAST

 

ADJUST DEVIATION

SELECT WITH

OR

THEN <ENTERN>

DEVIATION ADJUST :

VERTICAL WITH

OR

HORIZONTAL

WITH

OR

<EXIT>

to return.

Orbiting Alignment

Preparation :

Before proceeding to the alignment of the Orbiting default settings, be sure that the Horizontal Phase and the Raster shift are correctly aligned with the Orbiting mode set to OFF.

This alignment must be performed in case of a multiple projector installation with Master and Slave projectors in order to ensure a correct operation of the Orbiting for all projectors.

Adjustment procedure Stand-Alone projector :

Highlight 'ADJUST DEVIATION' with the control stick and press

ENTER.

When adjusting the horizontal and the vertical deviation, the picture moves in the corresponding direction, allowing the set up of the deviation without orbiting operation.

Push the control stick to the right or backward to toggle between Hor. and Vert. deviation andjustment.

Adjust horizontal deviation by pushing the control stick to the left or to the right

Adjust vertical deviation by pushing the control stick forward or backward

SLAVE ORBITING

CHANGE TO MASTER

ADJUST DEVIATION

SELECT WITH

OR

THEN <ENTERN>

DEVIATION ADJUST :

VERTICAL WITH

OR

HORIZONTAL

WITH

OR

<EXIT> to

return.

Horizontal

orbitampl.

60

Vertical

orbitampl.

60

A-2

 

5975268 BARCOGRAPHICS 1209s 010797

 

Page 54