Bosch Appliances 500 Alarms Menu, Aux Number, Function, Menu Item, Description, Options

Models: 500

1 56
Download 56 pages 16.43 Kb
Page 34
Image 34
Aux Number

34 en Navigating the MenusMIC Series 500 Camera

Aux Number

Function

 

 

1

Auto Focus

 

 

2

Digital Zoom

 

 

3

Auto Iris

 

 

5

Wiper

 

 

6

Washer

 

 

7

OSD

 

 

8

Backlight

 

 

To change a mapping, select the auxiliary number from the 8 available, press right to select, sand then scroll through the available functions using up and down control inputs.

5.8

Alarms Menu

The Alarms menu allows you to turn on and off alarm-related settings, learn alarm positions, and set the status of the two (2) alarm relays.

Learn alarm pos reacts differently depending on the current alarm mode. If Auto Alarm is on and Multi Alarm is off, this function saves the single Alarm Pos, which would be activated if the tamper switch is triggered. If Multi Alarm is on, you can select which alarm position to save by selecting Right, toggling up and down to the desired number, and then Right again to save.

A MIC power supply has a single tamper switch / alarm input built in; however, if more are required, a multi alarm plug-in board with 8 inputs and a washer drive function is available. Along with the 8 inputs, the multi alarm card also features 2 output relays, which can be used to either reset the activated alarm, or provide a signal to some other equipment.

The following settings control the behavior of the MIC 500 Series Camera as it detects different alarm signals.

MAIN MENU

1/2

MIC SETUPS

ACTIVATE FEATURE

PRESET TOUR

PATTERN TOUR

PRESETS

COMMUNICATIONS

ADVANCED SETUPS

ALARMS

..ALARMS..

1/2

AUTO ALARM OFF

 

MULTI ALARM

OFF

ALARM REARM

60 S

MANUAL CONTROL

 

LEARN ALARM POS

 

RELAY 1 STATUS

 

SET WITH ALARM

1-4

NORMALLY CLOSED

 

..ALARMS..2/2

RELAY 2 STATUS: SET WITH ALARM 5-8

NORMALLY CLOSED

Menu Item

Description

Options

 

 

 

AUTO ALARM

Enables use for both single or multi alarm functionality. With Auto Alarm

ON/OFF

 

on and Multi Alarm off, the unit monitors the tamper switch line, moving

 

 

to the programmable Alarm Position when the connection is grounded.

 

 

If Auto Alarm is turned off, the camera ignores any changes in the status

 

 

of the tamper line.

 

 

 

 

MULTI ALARM

Enables you to set up a separate position for each of the eight (8) alarm

ON/OFF

 

inputs. Any given alarm input triggers the camera to move to the

 

 

position to which it is associated. To enable this function, turn on Auto

 

 

Alarm and Multi Alarm.

 

 

 

 

ALARM REARM

See Section 5.8.1 Alarm Relays and Re-arm Time, page 35.

1/5/10/60 sec.

 

 

 

F.01U.173.601 2.0 2010.11

User’s Manual

Bosch Security Systems, Inc.

Page 34
Image 34
Bosch Appliances 500 user manual Alarms Menu, Aux Number, Function, Menu Item, Description, Options