MIC Series 500 CameraNavigating the Menus en 31
5.7 | Advanced Setups Menu |
The ADV SETUPS menu enables the user to access settings that would not be modified on a regular basis. It is recommended that these settings be removed from normal access.
MAIN MENU | 1/2 |
MIC SETUPS
ACTIVATE FEATURE
PRESET TOUR
PATTERN TOUR
PRESETS
COMMUNICATIONS
ADVANCED SETUPS
ALARMS
..ADV SETUPS..
CLEAR SOFTSTOPS
MANUAL CONTROL WASH WIPE POS SET ZERO POS UPPER LEFT SOFTSTOP LOWER RIGHT SOFTSTOP LEFT AUTOPAN LIMIT RIGHT AUTOPAN LIMIT
..ADV SETUPS.. |
| 1/4 |
IMAGE FLIP | ON |
|
PAN REVERSE |
| ON |
TILT REVERSE |
| ON |
SPEED SCALE | 10/10 |
|
WIPE MODE | NORMAL | |
HOME TIME | 5 MIN |
|
AUTO LOWLIGHT | OFF |
..ADV SETUPS..
MAP AUX TO PRESET FIND END STOPS RESET TO DEFAULTS
| ..ADV SETUPS.. | 2/4 | |
| POS DISPLAY LINE | 10 | |
| MIN INT SPEED 25 FPS | ||
| MAX GAIN LVL 28 DB |
| |
| OFF | ||
| AUTOPAN SPEED | 26 | |
| PROPORTIONAL PTZ ON | ||
| PAN TIMEOUT |
| |
|
|
|
|
4/4 |
|
| |
|
| ||
|
|
|
|
Menu Item | Description | Options | Default |
|
|
|
|
IMAGE FLIP | Manually inverts the image from the camera module, which may be | ON/OFF | OFF |
| used on an inverted camera where the head cannot be rotated through |
|
|
| 180 degrees. Note: Inverting the image normally requires some |
|
|
| modification of the control direction. |
|
|
|
|
|
|
PAN REVERSE | Reverses the direction of the pan control. When the camera is inverted, | ON/OFF | OFF |
| this returns the pan control to the correct direction. Ideal for use to |
|
|
| regain logical control if the unit was inverted. |
|
|
|
|
|
|
TILT REVERSE | Inverts the tilt rotation of the camera. Reverses the direction of the tilt | ON/OFF | OFF |
| control. When the camera is inverted, this returns the tilt control to the |
|
|
| correct direction. For use when the camera is mounted upside down. |
|
|
|
|
|
|
SPEED SCALE | This feature provides a way of adjusting the responsivity of the camera | 10/10 | |
| with respect to manual control inputs. The range is from 1 to 20, with |
|
|
| the speed scale approximately matching 5%, so 1 provides a speed |
|
|
| response of 5% and 20 provides full speed at 100%. |
|
|
|
|
|
|
Bosch Security Systems, Inc. | User’s Manual | F.01U.173.601 2.0 2010.11 |