Bosch Appliances user manual Appendices, MIC 500 Series Aux Controls

Models: 500

1 56
Download 56 pages 16.43 Kb
Page 51
Image 51

MIC Series 500 Camera en 51

A

Appendices

 

A.1

MIC 500 Series Aux Controls

 

The following table identifies the Auxiliary (Aux) codes of a MIC running Bosch protocol.

 

Table 1.1

 

 

 

 

 

 

Au

Setting

Values Available

 

x

 

 

 

 

 

 

 

2

Auto Pan

On: Starts Auto Pan between Scan Limits.

 

 

 

Tilt can be adjusted.

 

 

 

Off: Stops Auto Pan.

 

 

 

 

 

3

Iris Control

On: Iris Auto

 

 

 

Off: Iris Manual

 

 

 

 

 

4

Focus Control

On: Focus Auto

 

 

 

Off: Focus Manual

 

 

 

 

 

7

Plays Pre-position Tour 2

On: Starts Tour 2

 

 

 

Off: Stops Tour 2

 

 

 

 

 

8

Plays Pre-position Tour 1

On: Starts Tour 1

 

 

 

Off: Stops Tour 1

 

 

 

 

 

9

Inactive Home Return

On: Toggles between Return Home (Preset 99) or

 

 

 

Return Pre-position Tour (Inactivity after 300 seconds.)

 

 

 

Off: Inactive Home Return OFF

 

 

 

 

 

50

Play Pattern Tour 1

On: Plays Pattern 1

 

 

 

Off: Stops playing Pattern 1

 

 

 

 

 

52

Play Pattern Tour 2

On: Plays Pattern 2

 

 

 

Off: Stops playing Pattern 2

 

 

 

 

 

100

Record Pattern Tour 1

On: Records Pattern 1

 

 

 

Off: Stops recording Pattern 1

 

 

 

 

 

101

Record Pattern Tour 2

On: Records Pattern 2

 

 

 

Off: Stops recording Pattern 2

 

 

 

 

 

246

Fast Address Stage 1

On: Continues to Stage 2 in Fast address reprogram

 

 

 

Off: Cancels fast address reprogram

 

 

 

 

 

292

Fast Address Stage 2

On: Continues to Stage 3, which requires controller to move

 

 

 

to new address and “PRESS ON 1 ENTER”

 

 

 

Off: Cancels fast address reprogram

 

 

 

 

 

401

Wiper

On: Closes Wiper Relay

 

 

 

Off: Opens Wipe Relay

 

 

 

 

 

402

Washer

On: Closes Washer Relay (Wipes if washwipe is enabled)

 

 

 

Off: Opens Washer Relay

 

 

 

 

 

417

Protocol Change Stage 1

Continues to Stage 2

 

 

 

 

 

418

Protocol Change Stage 2

Takes next Aux as Protocol and Address Byte

 

 

 

 

 

420

On Screen menu

Displays On Screen Menu

 

 

 

 

Bosch Security Systems, Inc.

User’s Manual

F.01U.173.601 2.0 2010.11

Page 51
Image 51
Bosch Appliances user manual Appendices, MIC 500 Series Aux Controls