30 en Navigating the MenusMIC Series 500 Camera

5.5.3

Manual Control

 

The MANUAL CONTROL feature enables the user to manually control the unit for ten (10)

 

seconds while setting a preset position. A time remaining caption counts down at the top of

 

the screen. At the end of the countdown, the unit stops in its current position. If more

 

movement is required, press right on the Manual Control. This allows the user an additional

 

ten (10) seconds of manual control.

5.6Communications Menu

The communications page provides the selection of the MIC Address, Protocol and Baud Rate. Once modified, the settings only take effect once the menu has been exited and the confirmation page has been accepted. The address field allows values in the range 1 to 254, this will be carried over between protocols.

The MIC 500 Series Camera provides twin protocol support in one release of software. The camera's operating protocol can be switched using the Cam-set or the “Protocol” setting in this menu section. The protocol pack options are: FV/Bosch (default), FV/Pelco and FV/VCL.

MAIN MENU

1/2

MIC SETUPS

ACTIVATE FEATURE

PRESET TOUR

PATTERN TOUR

PRESETS

COMMUNICATIONS

ADVANCED SETUPS

ALARMS

..COMMUNICATIONS..

ADDRESS

1

 

PROTOCOL

BOSCH

BAUD RATE

 

 

-------------------------------------------

: WARNING CHANGING :

: ANY SETTING MAY

:

: CAUSE A LOSS OF

:

: CONTROL

 

:

Menu Item

Description

 

 

ADDRESS

Allows the appropriate camera to be operated via the numerical address in the control system. The

 

address may be set locally using Cam-set. To change the address using Cam-set, enter the desired

 

address in the New Address field then, press Configure MIC Communications. The MIC

 

Communications Settings menu is displayed. Modify the settings then, press Apply (optional 1-254

 

addresses).

 

 

PROTOCOL

Enables the user to switch between the protocols in the loaded protocol pack. Options are: FV/

 

Bosch (default), FV/Pelco or FV/VCL.

 

 

BAUD RATE

Enables the user to toggle between 4800 and 9600 Baud rate. The speed at which

 

telecommunication data is transmitted, measured in bits per second (Bps).

 

 

 

The “Baud Rate” setting provides a full range of values, 1200, 2400, 4800, 9600, 19200 or

 

38400 for each protocol. Not all protocol controllers support this full range, so ensure that the

 

correct option is selected before confirming.

 

Modifying any of these parameters and then confirming the selection causes immediate loss

 

of control until the control system is reconfigured to match. If a protocol, address or baud

 

rate option is made that cannot be obtained through the control system, the camera must be

 

reset using the Configure MIC Communications function of Cam-set.

 

Modifying any of these values invokes an extra page to appear when exiting the menu. To

 

accept the changes made, move the line down to APPLY SETTINGS and press right. To ignore

 

them, press right on DISCARD SETTINGS.