30 en Navigating the MenusMIC Series 500 Camera
5.5.3 | Manual Control |
| The MANUAL CONTROL feature enables the user to manually control the unit for ten (10) |
| seconds while setting a preset position. A time remaining caption counts down at the top of |
| the screen. At the end of the countdown, the unit stops in its current position. If more |
| movement is required, press right on the Manual Control. This allows the user an additional |
| ten (10) seconds of manual control. |
5.6Communications Menu
The communications page provides the selection of the MIC Address, Protocol and Baud Rate. Once modified, the settings only take effect once the menu has been exited and the confirmation page has been accepted. The address field allows values in the range 1 to 254, this will be carried over between protocols.
The MIC 500 Series Camera provides twin protocol support in one release of software. The camera's operating protocol can be switched using the
MAIN MENU | 1/2 |
MIC SETUPS
ACTIVATE FEATURE
PRESET TOUR
PATTERN TOUR
PRESETS
COMMUNICATIONS
ADVANCED SETUPS
ALARMS
..COMMUNICATIONS..
ADDRESS | 1 |
|
PROTOCOL | BOSCH | |
BAUD RATE |
|
|
: WARNING CHANGING : | ||
: ANY SETTING MAY | : | |
: CAUSE A LOSS OF | : | |
: CONTROL |
| : |
Menu Item | Description |
|
|
ADDRESS | Allows the appropriate camera to be operated via the numerical address in the control system. The |
| address may be set locally using |
| address in the New Address field then, press Configure MIC Communications. The MIC |
| Communications Settings menu is displayed. Modify the settings then, press Apply (optional |
| addresses). |
|
|
PROTOCOL | Enables the user to switch between the protocols in the loaded protocol pack. Options are: FV/ |
| Bosch (default), FV/Pelco or FV/VCL. |
|
|
BAUD RATE | Enables the user to toggle between 4800 and 9600 Baud rate. The speed at which |
| telecommunication data is transmitted, measured in bits per second (Bps). |
|
|
| The “Baud Rate” setting provides a full range of values, 1200, 2400, 4800, 9600, 19200 or |
| 38400 for each protocol. Not all protocol controllers support this full range, so ensure that the |
| correct option is selected before confirming. |
| Modifying any of these parameters and then confirming the selection causes immediate loss |
| of control until the control system is reconfigured to match. If a protocol, address or baud |
| rate option is made that cannot be obtained through the control system, the camera must be |
| reset using the Configure MIC Communications function of |
| Modifying any of these values invokes an extra page to appear when exiting the menu. To |
| accept the changes made, move the line down to APPLY SETTINGS and press right. To ignore |
| them, press right on DISCARD SETTINGS. |
F.01U.173.601 2.0 2010.11 | User’s Manual | Bosch Security Systems, Inc. |