MIC Series 500 CameraNavigating the Menus en 25
Menu Item | Description |
|
|
AUTO FLIP | When enabled this command automatically flips the video picture and PTZ controls to enable |
| easy control when the camera is inverted. Controls remain reversed until a stop command is |
| received, at which point they return to normal. |
|
|
SELF DIAGNOSIS | Runs rudimentary tests indicating any faults with the unit. The test begins with the unit moving |
| to a specified test position and then checking for valid resolver readings and reliable camera |
| module communications. Then, the pan and tilt drives and camera zoom are tested. Finally, the |
| wiper is activated. The results of each test are displayed as completed, refer to Section 5.16 Self |
| Diagnosis, page 50. |
|
|
The Config settings are available through the menu and offer the user a quick way of setting up the MIC 500 Series Camera for different configurations. Table 5.2 and Table 5.3 indicate the options available and which settings are changed when these are set.
The settings modified by these (for example, Image Flip, Pan Reverse, Auto Alarm, etc.) can also be individually set elsewhere in the menu; however the “Config” settings retain their current value, which may lead to confusion over the current MIC 500 Series Camera state. It is advised that the individual settings are not changed unless specifically required.
Setting | Options | Default |
|
|
|
Config | Upright/Canted/Inverted | UPRIGHT |
|
|
|
Auto Home | ON/OFF | OFF |
|
|
|
Home To | Preset/Tour | TOUR |
|
|
|
ON/OFF | OFF | |
|
|
|
OSD | ON/OFF | OFF |
|
|
|
Pos Display | ON/OFF | OFF |
|
|
|
Auto Alarm | ON/OFF | OFF |
|
|
|
Digital Zoom | ON/OFF | OFF |
|
|
|
Auto Flip | ON/OFF | OFF |
|
|
|
Self Diagnosis | N/A |
|
|
|
|
Table 5.1 MIC 500 Series Camera Settings and Options