MIC Series 500 Camera

Navigating the Menus en 27

 

 

:PRESET

: DWELL

-----------------------------------------------

1:1

2:2

3:RANDOM

4:RANDOM

5:5

:5

:DEFAULT

:5

:RANDOM

:5

Menu Item

Description

 

 

NUMBER OF TOUR

The number of tour points ranges from 1 to 32, with each point having an available

POINTS

preset position and dwell time, programmable on the Create / Modify Tour page.

 

 

TOUR POINT SETTINGS

Contains the default and random limit settings. The settings are separated into Dwell

 

and Preset sub headings. If a tour point is defined to use a random preset or random

 

dwell, the values remain within the bounds set on this page.

 

 

CREATE/MODIFY TOUR

Shows a list of the individual tour points in a tabular fashion. The number of points

 

available is defined by the setting on the previous page. Up and down controls move the

 

highlighted line to the next or previous tour point respectively, moving on to the next

 

page if the cursor is moved past the end (see Section 5.3.1 Create/Modify Tour, page 27).

 

 

RANDOM TOURS

Moves intelligently through the presets if the random option is chosen. It will not repeat

 

a given position until all preset in the selection have been visited.

 

 

5.3.1

Create/Modify Tour

 

To modify one of the settings, select the tour point by moving right, which will highlight the

 

line in green. The preset number will start flashing indicating this setting is now changeable

 

by toggling up and down.

 

Four (4) tours are programmable each with up to 32 steps. Each step can be individually

 

programmed with a preset position number (1 to 64) and a dwell time in seconds (1 to 240).

 

To change the dwell time, send another Right command which will start the dwell option

 

flashing, as before up and down changes this value.

 

To select Random or Default options, move the joystick to either end of the available options.

 

For presets, the random values are between 1 and 64. For dwell times, random and default

 

settings are between 1 and 240.

5.3.2

Random Tours

 

 

 

 

To make the random options work, a few limits must be set up which indicate the range of

 

 

presets available, and the time scale available for dwell times. For example, setting a preset

 

 

position as Random and the limits as 5 and 20 respectively, the camera moves to a random

 

 

preset position between 5 and 20 and waits there for the given dwell time, which can also be

 

 

random and operates in the same way. Alternatively, for the dwell there is a default option,

 

 

the value of which can also be changed to the users requirements.

 

 

Example of tour setup:

 

 

 

 

 

 

 

 

 

Tour Setting

Value

 

 

 

 

 

 

 

 

Min. Random Preset Position

5

 

 

 

 

 

 

 

 

Max. Random Preset Position

15

 

 

 

 

 

 

 

 

Min. Random Dwell Time

10

 

 

 

 

 

 

Bosch Security Systems, Inc.

User’s Manual

F.01U.173.601 2.0 2010.11

Page 27
Image 27
Bosch Appliances 500 user manual Create/Modify Tour, Random Tours, Tour Setting Value