Bosch Appliances D1260B CHG RELAYS ? COMMAND + 5 +, CHG PASSCODES ? COMMAND + 5 +, Description

Models: D1260B D1260

1 100
Download 100 pages 63.09 Kb
Page 51
Image 51
CHG RELAYS ? (COMMAND + 5 + 4)

D1260/D1260B Owner's Manual Part III: Advanced Commands - CHG RELAYS ? (COMMAND + 5 + 4)

CHG RELAYS ? (COMMAND + 5 + 4)

Your security company may program relays for automatic control and/or control from your keypad of devices such as premises lighting or entry gates. Contact them for further information regarding the use of relays in your security system.

1.Ensure your keypad shows idle disarmed text.

2.Press the COMMAND key. The display shows *System Command*.

3.Press the 5 key and then the 4 key.

If you prefer, you may use the Command Menu in place of steps 2 and 3 to initiate this function.

Press the MENU> soft key to enter the

Command Menu.

Press NEXT> soft key repeatedly.

When you reach the CHG RELAYS ?> prompt, press its adjacent soft key.

4.The command center display changes *Change Relay* Enter relay number:

Valid entries are 1 to 128, depending how the system is configured.

Enter the relay number then press either the Enter> soft key or the ENTER button.

5.If the relay is valid and turned off, the display changes to Change Relay* Relay 123 is currently off.

(123 is used as an example.)

Press the Turn on> soft key to turn on the relay.

6.If the relay is valid and turned on, the display changes to Change Relay* Relay 123 is currently on.

(123 is used as an example.)

Press the Turn off> soft key to turn off the relay.

7.The display returns to the *Change Relay* Enter relay number:

Press the <Exit soft key to return to idle text.

CHG PASSCODES ? (COMMAND + 5 + 5)

Description

Use this function to change your personal passcode without assistance from the security company.

Before you begin:

Choose a new passcode three to six digits long. If you choose a passcode with the same digit in consecutive order (for example “33” in 334697), take care when entering it.

Bosch Security Systems 9/04 50410D

51

Page 51
Image 51
Bosch Appliances D1260B CHG RELAYS ? COMMAND + 5 +, CHG PASSCODES ? COMMAND + 5 +, Press the MENU> soft key to enter the