D1260/D1260B Owner's Manual Part III: Advanced Commands - ADD/CHANGE USER (COMMAND + 5 + 6)

If the passcode does not match, the command center will emit an error tone and display Passcode not changed.

5.Press the <Exit soft key to return to the Add/Change Menu.

Add/Change Level

1.Pressing the <Level or the Level> soft key will allow you to add/change a user’s authority level.

2.The display changes to User 123 Add Auth. Level for this user?

Press the Yes> soft key to add an Authority Level.

Press the No> soft key to advance to Add/Change Passcode - if the panel is a D9112 or a D7212) or to Change Sub-User ID - if the panel is a D9412 or a D7412.

Press the <Exit soft key to exit out of this menu and return to the Level changed. display (Refer Step 7).

3.The display changes to Is this user authorized in Area 1?

Press the Yes> soft key to/add change this user’s authority level in Area 1.

Press the No> soft key if the user isn’t authorized in Area 1 and proceed to display user’s authorization in Area 2.

Press the <Exit soft key to exit out of this menu and return to the Level changed display.

If the user is authorized in Area 1, the displays changes to User’s current authority level: 14 for Area 1.

(14 is used as an example here)

To change the Authority Level, Enter a new authority level (from 1 to 14), if desired, and press either the Enter> soft key or the ENTER button.

Before determining the Authority Level for a user, please consult your security company to assist you in selecting the correct authority level.

Press the <Exit soft key to exit out of this menu and return to the Level changed display.

4.Repeat Step 3 for each area through Area 8.

5.The display changes to User 123 Change this user’s Auth. Level?

Press the Yes> soft key to add/change this user’s authority level in Area 1.

Press the No> soft key to advance to Add/Change Passcode (if the panel is a D9112 or a D7212) or to Change Sub-User ID (if the panel is a D9412 or a D7412).

Press the <Exit soft key to exit out of this menu and return to the Level changed. display (refer to Step 7).

If the user is authorized in Area 1, the displays changes to User’s current authority level: 14 for Area 1.

(14 is used as an example here)

To change the Authority Level, Enter a new authority level (from 1 to 14), if desired, and press either the Enter> soft key or the ENTER button.

Before determining the Authority Level for a user, please consult your security company to assist you in selecting the correct authority level.

56

Bosch Security Systems 9/04 50410D

Page 56
Image 56
Bosch Appliances D1260B owner manual Add/Change Level, Bosch Security Systems | 9/04 | 50410D