12. TREADLE UNIT

 

 

 

 

 

 

 

 

 

 

 

 

12-2. Standard setting values

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SPECIFICATIONS

Treadle unit -G

 

Treadle unit -H

 

 

 

 

 

Operation

Automatic presser

foot lifting

Automatic presser foot lifting

 

 

Function

Signal

does not occur

 

 

occurs

 

 

 

 

 

 

 

 

 

 

No modulation at 1st step forward

 

Modulation at 1st step

forward

 

 

No.

(Diagram

Spring position setting

or backward

 

 

and backward

 

 

 

 

below)

 

 

 

 

 

 

 

(Figure [a] on previous page)

 

(Figure [b] on previous page)

 

 

 

 

 

 

 

 

 

 

Function

Length from S0

Force

 

Length from S0

 

Force

 

 

 

 

(mm)

(N)

 

(mm)

 

(N)

 

 

 

 

 

 

 

 

 

-

S0

Neutral point

0

-

 

0

 

-

 

 

82

S1

Forward automatic

-

-

 

2 (*1)

 

10

 

 

presser foot lifting point

 

 

 

 

 

 

 

 

 

 

 

 

 

 

83

S2

Low speed operation

3

10

 

5

 

25

 

 

starting point

 

 

 

 

 

 

 

 

 

 

 

 

 

 

84

S3

Speed change starting

6

-

 

7

 

-

 

 

point

 

 

 

 

 

 

 

 

 

 

 

 

 

 

85

S4

Maximum speed arrival

S5-1

-

 

S5-1

 

-

 

 

point

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-

S5

Maximum forward

14.5

12

 

14.5

 

32

 

 

depression point

 

 

 

 

 

 

 

 

 

 

 

 

 

 

81

S6

Backward automatic

-

-

 

2 (*2)

 

14

 

 

presser foot lifting point

 

 

 

 

 

 

 

 

 

 

 

 

 

 

80

S7

Thread trimming

5

22

 

5

 

35

 

 

operation point

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-

S8

Maximum backward

8

28

 

8

 

43

 

 

depression point

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(*1) Enabled when DIP switch No. 1 is set to “ON” and memory switch No. 13 is set to “1”.

 

 

 

 

 

(*2) Enabled when memory switch No. 12 is set to “0”.

 

 

 

 

 

 

When the connecting rod installation position is on the inside, the setting value is the amount of movement when the treadle is depressed forward or backward.

For treadle unit -H, the point (F) where the forward depression force changes is in between S1 and S2, and the point (R) where the backward depression force changes is between S6 and S7.

Sewing

speed

Depressed backward

Neutral

Depressed forward

1841M

 

 

 

Z-8550A, 8560A

104