3. FUNCTION SETTINGS
3-3. Data initialization
Initialization of memory data refers to returning all operation panel setting data (including data that has been set using memory switches) to the factory default settings.
1 While holding down the RESET key on the operation panel, turn on the power switch (1).
Orange display
3457M
2 | Green display |
|
The operation panel settings will be returned to their factory defaults.
After this, operation panel and treadle operation will be
possible.
<Initialization of speed data only>3458M
1 While holding down the MAX key on the operation panel, turn on the power switch (1).
Orange display
0170B
2 | Green display |
|
The speed data will be set to the speed data for the machine head detection unit.
After this, operation panel and treadle operation will be possible.
0171B
14 |