3. FUNCTION SETTINGS

 

 

 

 

 

 

 

Memory switch No. 68 - 69

 

 

 

 

No.

Initial value

Setting range

Setting details

 

 

 

 

 

Seam matching function during automatic backtacking

 

 

68

 

 

(Used when you would like seams to be accurately matched when using

 

 

0

0 - 1

automatic backtacking; No. 78 sets the stop position and No. 79 can be

 

 

 

used to change the time until restart.)

 

 

 

 

 

 

 

 

 

 

0: No stopping when material feed direction is changed

 

 

 

 

 

1: Momentarily stops when material feed direction is changed

 

 

 

 

 

Actuator (optional part) function

 

 

 

 

 

0: Function is disabled

 

 

69

1

0 - 3

1: Stitch counter actuator

 

 

2: Sewing speed actuator

 

 

 

 

 

3: Option actuator

 

 

 

 

 

(When set to “2”, reflection pattern sewing using the sewing machine

 

 

 

 

 

actuator switch is disabled. Correction sewing is enabled.)

 

<When set to stitch counter actuator>

Connect to connector P17 (OPT_SW) on the main circuit board.

1:Stitch counter actuator

2:Reflection pattern switch

1:Stitch counter warning LED

2: Reflection pattern LED

2249M

When the number of stitches displayed in the stitch counter reaches “-0”, the stitch counter warning LED illuminates. (This is the same function as the “!” con display on the operation panel.)

When the stitch counter actuator is pressed, the stitch counter warning LED switches off and treadle operation is enabled. (This is the same operation as when the RESET switch is pressed.)

Memory switch No. 74 - 79

No.

Initial value

Setting range

Setting details

74

15 degrees

-345 - 345

Quick reverse solenoid on timing during start backtacking/continuous

(degrees)

backtacking

 

 

75

-30 degrees

-345 - 345

Quick reverse solenoid off timing during start backtacking/continuous

(degrees)

backtacking

 

 

76

-30 degrees

-345 - 345

Quick reverse solenoid off timing during end backtacking

(degrees)

 

 

 

77

15 degrees

-345 - 345

Quick reverse solenoid on timing during end backtacking

(degrees)

(Enabled when No. 22 or No. 26 is set to “1”)

 

 

78

180 (degrees)

0 - 350

Momentary stopping position when material feed direction is changed

(Enabled when No. 68 is set to “1”)

 

(degrees)

 

 

The stopping position is the angle from when the needle up signal turns on.

 

 

 

79

100 (ms)

10 - 500 (ms)

Momentary stopping time when material feed direction is changed

(Quick reverse mechanism switches at stopping position. After the stopping

 

 

 

time has elapsed, sewing starts again automatically.)

<Settings for memory switch No. 74 - 77>

When set to negative (-) settings with the initial values as a reference, the quick reverse solenoid ON/OFF timing will become faster. If the seams are too short immediately before changing occurs, change the setting in the (-) direction.

When set to positive (+) settings with the initial values as a reference, the quick reverse solenoid ON/OFF timing will become slower. If the seams are too short immediately after changing occurs, change the setting in the (+) direction.

Z-8550A, 8560A