3. FUNCTION SETTINGS

3-2. List of memory switch settings

Memory switch No. 0 - 15

No.

Initial value

Setting range

Setting details

 

 

 

 

Needle up stop position setting

 

0

0 (degrees)

-10 - 10

 

 

(degrees)

Higher

Lower

 

 

 

 

 

 

 

 

 

0212B

 

 

 

 

 

 

 

 

Needle down stop position setting

 

1

0 (degrees)

-10 - 10

 

 

(degrees)

Higher

Lower

 

 

 

 

 

 

 

 

 

0212B

 

 

 

 

 

 

 

Depressing treadle forward when treadle is depressed backward (thread

2

0

0 - 1

trimming)

 

0: Disabled (Enabled after treadle is returned to neutral position and then

 

 

 

depressed forward)

 

 

 

 

1: Enabled

 

3

1

0 - 1

Power supply voltage drop check (reset detection) function

0: None

 

 

 

 

1: Enabled, [Err 95] displayed when voltage drops.

 

4

0

0 - 1

Buzzer (electronic sound) during panel operation

 

0: Yes

 

 

 

 

1: None

 

5

0

-

[Do not change this setting.]

 

6

0

0 - 1

Piercing force boosting operation

 

0: Yes

 

 

 

 

1: None

 

7

0

0 - 1

End backtacking speed

 

0: Limited by speed bar key setting

 

 

 

 

1: Not limited by speed bar key setting

 

9

0

0 - 1

End backtacking sewing speed

 

0: Speed can be set independently from start backtacking speed

 

 

 

1: Speed is set to start backtacking speed

 

 

 

 

Presser foot condition when treadle is returned to neutral position after

12

0

0 - 1

thread trimming

 

0: Presser foot is lowered (it is not lowered when DIP switch 1 is OFF)

 

 

 

 

 

 

1: Presser foot is not lowered

 

13

0

0 - 1

Presser foot condition when operation stops at the neutral treadle position

0: Presser foot is not lifted

 

 

 

 

1: Presser foot is lifted

 

 

 

 

Actuator function

 

14

0

0 - 1

0: Operates as a reverse stitch switch during sewing, and as a correction

stitch switch when sewing is stopped

 

 

 

 

 

 

 

 

1: Thread trimming switch

 

15

0

0 - 1

Deceleration stop control when treadle is returned to neutral position

0: Deceleration stop control without single stitch advance

 

 

 

 

1: Above control is not carried out

 

Z-8550A, 8560A