8. CHANGING THE FEED AMOUNT TO LONG STITCH SPECIFICATIONS (from 2.0mm to 5.0mm)

5.Turn the stitch length dial (7) and the condense dial (8) to the maximum feed amount for the feed dog being used. (Set the condense dial (8) to a negative number.)

3501M

3502M

[A]

1179B

[B]

1180B

6.Check that the feed dog does not touch the needle plate both when the reverse stitching lever (9) is not lowered and when it is lowered.

If it touches, adjust the forward/back installation position (centering) of the feed dog.

7.Without lowering the reverse stitching lever (9), move the stopper (5) up until it touches F-regulator connecting rod (10), and then tighten the screw (3). [Fig. A]

8.With the reverse stitching lever (9) lowered all the way, move the stopper (6) down until it touches the F-regulator connecting rod (10), and then tighten the screw (4). [Fig. B]