3. FUNCTION SETTINGS
Memory switch No. 31 - 46No. | Initial value | Setting range | Setting details | |
|
|
| Stopping while start backtacking is in progress, and speed during start | |
|
|
| backtacking | |
|
|
| 0: When the treadle is returned to the neutral position, start backtacking | |
31 | 0 | 0 - 1 | ends, sewing stops and the sewing speed becomes the start backtacking | |
(constant) speed | ||||
|
|
| 1: When the treadle is returned to the neutral position, start backtacking can | |
|
|
| be stopped before it is finished, and the speed during start backtacking | |
|
|
| becomes the speed corresponding to the treadle depression amount (low | |
|
|
| speed - start backtacking speed) | |
32 | 300 (ms) | 10 - 990 (ms) | Fully on time for presser foot lifter solenoid | |
33 | 0 | 0 - 1 | Fixed stitch function using actuator switch | |
0: None | ||||
|
|
| 1: Yes | |
|
|
|
| |
35 | 0 | 0 - 1 | Presser foot soft down mode | |
0: Automatic mode (Adjustment required using No. 39) | ||||
|
|
| 1: Manual mode (Adjustment required using No. 38) | |
36 | 180 (seconds) | 0 - 240 | Presser foot lift time | |
0: No timer function (is not lowered) | ||||
(3 minutes) | (seconds) | |||
| ||||
|
|
| ||
37 | 0 | 0 - 1 | Model setting for automatic presser foot lifter | |
0: Solenoid type (Duty while chopping can be varied using No. 115) | ||||
|
|
| 1: Pneumatic type (Duty while chopping can be varied using No. 116) | |
38 | 40 (ms) | 20 - 120 (ms) | Delay time from presser foot lowering command until presser foot lifter | |
solenoid momentarily turns on (only enabled when No. 35 is set to “0”) | ||||
|
|
| ||
|
|
| Sensing voltage constant from presser foot lowering command until presser | |
39 | 12 | 10 - 12 | foot lifter solenoid momentarily turns on (only enabled when No. 35 is set to | |
“0” | ||||
|
|
| If it is set to “10”, the response will be fastest and the operating noise will be | |
|
|
| loudest. | |
|
|
| Operation when presser foot is lifted and lowered using knee switch | |
40 | 0 | 0 - 1 | This setting is only enabled when DIP switch No. 1 is set to “OFF”. | |
0: Presser foot cannot be lifted or lowered by depressing the treadle | ||||
|
|
| backward | |
|
|
| 1: The above operation is possible. | |
|
|
| Presser foot lifting after treadle is returned to neutral position so sewing | |
41 | 0 | 0 - 1 | stops, and is then depressed backward to the 1st step | |
0: Possible | ||||
|
|
| 1: Not possible | |
|
|
| When No. 42 is set to “1”, this function operates as though set to “0”. | |
|
|
| Operation when treadle is depressed backward | |
|
|
| 0: Thread trimming operation | |
42 | 0 | 0 - 1 | 1: Thread trimming operation is disabled (presser foot is lifted when treadle | |
is depressed backward) | ||||
|
|
| ||
|
|
| (The default setting for standard specifications is “1”, and the default setting | |
|
|
| for other specifications is “0”.) | |
|
|
| Operation when standing operation variable speed pedal is on | |
44 | 0 | 0 - 2 | 0:Sewing speed is in accordance with treadle depression amount | |
1: Operation is at the sewing speed set by the speed bar key (constant | ||||
|
|
| speed) | |
|
|
| 2: Operation is at end backtacking speed | |
45 | 80 (ms) | 0 - 500 (ms) | Delay time for motor to start when standing operation pedal turns on. | |
|
|
| Operation during standing operation when AUTO function is on | |
46 | 0 | 0 - 1 | 0: Sewing stops before finished when presser lifter pedal turns on | |
(momentary stop operation) | ||||
|
|
| ||
|
|
| 1: Above function is disabled |
6 |