3. FUNCTION SETTINGS
Memory switch No. 90 - 110No. | Initial value | Setting range |
| Setting details |
| |
90 | 160 | 150 - INCH | Thread trimming speed (TRIM) |
| ||
(rpm) | (rpm) |
| ||||
|
|
|
| |||
91 | 220 | 150 - 300 | Low speed (INCH) |
|
| |
(rpm) | (rpm) |
|
| |||
|
|
|
| |||
92 | 1400 | 500 - 2500 | Stop improvement position (POS) |
| ||
(rpm) | (rpm) | [Do not change this setting.] |
|
| ||
|
|
| ||||
93 | 300 | INCH - 1000 | Slow speed (SLOW) |
|
| |
(rpm) | (rpm) |
|
| |||
|
|
|
| |||
94 | 3000 | INCH - 3000 | Start backtacking limit speed (SBL) |
| ||
(rpm) | (rpm) | (Upper limit for start backtacking speed setting) |
| |||
|
| |||||
96 | 1200 | INCH - 3000 | End backtacking speed (EBT) |
|
| |
(rpm) | (rpm) |
|
| |||
|
|
|
| |||
98 | HIL | INCH - HIL | Automatic sewing speed (AUTO) |
| ||
(rpm) | (rpm) |
| ||||
|
|
|
| |||
99 | (*1) | INCH - 5000 | Maximum sewing speed limit speed (HIL) (*2) |
| ||
(rpm) |
| |||||
|
|
|
|
| ||
101 | 8.0 | 3.0 - 10.0 | Maximum zigzag width setting |
|
| |
(mm) | (mm) |
|
| |||
|
|
|
| |||
|
|
| Backtack zigzag width setting |
|
| |
102 | 0 | 0 - 1 | 0: Cannot be changed |
|
| |
|
|
| 1: Can be changed |
|
| |
|
|
| Backtack selection when plain zigzag is selected |
| ||
103 | 0 | 0 - 1 | 0: Plain zigzag |
|
| |
|
|
| 1: |
|
| |
|
|
| Pattern reset when treadle is depressed backward |
| ||
|
|
| 0: Starts from next pattern |
|
| |
104 | 0 | 0 - 2 | 1: Returns to start of patterns only if patterns 5 to 9 are selected | |||
2: Returns to start of patterns when plain, | ||||||
|
|
| ||||
|
|
| (patterns 2 to 9) |
|
| |
|
|
| (Plain, | |||
|
|
| Sewing start position when plain, | |||
|
|
| When stopped at left | Free | When stopped at right | |
105 | 0 | 0 - 1 | 0: Left edge | Left edge | Right edge | |
|
|
| 1: Right edge | Right edge | Left edge | |
|
|
| This setting is enabled when No. 104 is set to “2”. |
| ||
|
|
| Blind stitch sewing start position |
| ||
106 | 0 | 0 - 2 | 0: Zigzag section |
|
| |
1: Plain stitch section |
|
| ||||
|
|
|
|
| ||
|
|
| 2: Specified by the number of stitches |
| ||
|
|
| Sewing machine motor operation when [UP] is displayed | |||
108 | 0 | 0 - 1 | 0: Disabled (hand operation only) |
| ||
1: Operates (enabled when treadle depressed backward and | ||||||
|
|
| ||||
|
|
| pressed) |
|
| |
|
|
| Needle zigzagging when treadle depressed backward | |||
109 | 1 | 0 – 1 | 0: Disabled |
|
| |
|
|
| 1: Enabled |
|
| |
|
|
| Sewing patterns with changed sewing pitch (T stitches) | |||
110 | 0 | 0 - 1 | 0: Not possible |
|
| |
|
|
| 1: Possible |
|
|
*1: Setting is read from machine head detection switch.
*2: This is the upper limit setting for the maximum sewing speed. Refer to
10 |