3. FUNCTION SETTINGS

Memory switch No. 47 - 60

No.

Initial value

Setting range

Setting details

 

 

 

Operation during standing operation when AUTO function is on

47

0

0 - 1

0: When high-speed pedal turns on, sewing is momentarily stopped, and it

is resumed when pedal turns off.

 

 

 

1: Above function is disabled

 

 

 

This function is disabled when No. 49 is set to “1”.

 

 

 

Thread trimming pedal operation during standing operation after thread

48

0

0 - 1

trimming

0: Presser foot can be lifted and lowered

 

 

 

 

 

 

1: Above operation is disabled (only possible using presser foot lifter pedal)

 

 

 

Alternating operation of standing operation pedal and treadle

 

 

 

(Does not include operation of presser foot lifter pedal. In the case of

49

0

0 - 1

simultaneous operation, the standing operation pedal has priority.)

0: Treadle operation is disabled after standing operation pedal has been

 

 

 

used

 

 

 

1: Treadle operation is still enabled after standing operation pedal has been

 

 

 

used (alternating operation is possible)

51*

0

0 - 1

Correction sewing using actuator switch after thread trimming

0: Forbidden (switch operation disabled)

 

 

 

1: Possible

52

2 (stitches)

1 – 99

Number of slow start stitches

(stitches)

 

 

 

53*

10 (stitches)

0 - 100

Counting units for stitch counter display

0: No counting operation

(stitches)

 

 

1-100: Display counts down by the set number of stitches

 

 

 

 

 

 

Stitch counter warning operation (when (!) icon is displayed)

 

 

 

0: Starting using treadle is always enabled

54*

1

0 - 2

1: Starting using treadle prevented (thread trimming is possible when

treadle is depressed backward)

 

 

 

 

 

 

2: Operation using treadle fully prevented when treadle is returned to

 

 

 

neutral position and sewing stops

 

 

 

Operation when treadle is depressed backward or knee switch operation

55

0

0 - 1

when presser foot is lifted

0: Presser foot lifts when treadle is returned to neutral position

 

 

 

 

 

 

1: Presser foot lowers when treadle is returned to neutral position

 

 

 

Function for preventing accidental forward depression of the treadle to

56

0

0 - 1

cause the needle bar to move after the treadle has been depressed

backward and is then returned to the neutral position

 

 

 

0: Yes

 

 

 

1: None

 

 

 

Operation when treadle is depressed forward to the 1st step when the

57

0

0 - 1

presser foot is lifted

0: Presser foot is lowered

 

 

 

 

 

 

1: Presser foot is not lowered

58

0

0 - 1

Presser foot soft lift function

0: None

 

 

 

1: Yes (Settings for No. 59 and No. 60 are required.)

 

 

 

Presser foot soft lift timer setting

59

0 (ms)

0 - 150 (ms)

(When No. 58 is set to “1”)

 

 

 

 

Presser foot lifting

60

0 (ms)

0 - 99 (ms)

(Fully on)

 

 

 

2247M

 

 

 

 

* : Settings indicated with * are enabled after the power is turned off and then back on again.

7