11. ELECTRICAL MECHANISM
11-3. Description of fuses
When replacing the fuses and fuse resistors, be sure to use the parts specified below.
If the components on the P.C. boards are damaged, the fuses may blow again soon even after they have been replaced.
| No. | Part name | Parts code | Symptom when fuse blows | ||
|
| 200 V | Fuse 10A | J | Power does not turn on and red LED (1) on | |
F1, |
| system | (Glass tube fuse | power supply P.C. board does not illuminate. | ||
|
| |||||
|
|
|
|
| ||
F2 |
| 100 V | Fuse 20A | J | Power does not turn on and red LED (1) on | |
|
| system | (Glass tube fuse | power supply P.C. board does not illuminate. | ||
|
|
| ||||
|
|
|
|
|
| |
| F3 | Fuse 5A | J | Needle zigzag motor does not operate and | ||
| (Glass tube fuse | [Err 200] is displayed. | ||||
|
|
|
| |||
| R70 | Fuse resistor 1/2W 0.47Ω | J | Needle zigzag motor does not operate and | ||
| [Err 200] is displayed. | |||||
|
|
|
|
| ||
| R73 | Fuse resistor 1/2W 0.22Ω | J | Needle zigzag motor does not operate and | ||
| [Err 200] is displayed. | |||||
|
|
|
|
| ||
R1, R2, R3 | Fuse resistor 1/4W 0.47Ω | J | Sewing machine motor does not operate and | |||
[Err 130] is displayed. | ||||||
|
|
|
|
| ||
| R4 | Fuse resistor 1/2W 0.47Ω | J | Sewing machine motor does not operate and | ||
| [Err 130] is displayed. | |||||
|
|
|
|
|
*The diagram of the power supply P.C. board shown below is for the 200 V systems. The power supply P.C. board for 100 V systems are the same as the one for 200 V systems except for the section indicated in the diagram.
100V0161B
90 |