3. FUNCTION SETTINGS
3-8. Needle zigzag home position adjustment procedure
OPERATION PROCEDURE1 While(1). pressing the [zigzag width/zigzag reference line position] key on the operation panel, turn on the power switch
The offset value will be displayed. (Initial setting is “0”)
0185B
2 Move the needle bar to the needle up stop position, and then press and hold the RESET key for 2 seconds or more.
Home position detection will be carried out, and then the needle bar will stop at the
After detection is complete, the [orG] display will stop flashing and illuminate steadily.
*If [Err 200] appears, it indicates that there is a problem with the needle zigzag motor home position.
*If [UP] appears, turn the pulley by hand to move the needle bar to the needle up stop position, and then press the RESET key once more. Home position detection will be carried out.
0186B
3 Use the home position checking tool, and press the [ U / V ] keys to change the offset value
The needle bar will move in accordance with the setting value.
When the setting has been changed, the [orG] display will change from illuminated to flashing.
|
| 0187B |
|
| |
4 | Move the needle bar to the needle up stop position, and then press the RESET key. | |
| Home position detection will be carried out. | |
|
| After detection is complete, the [orG] display will stop flashing and |
|
| illuminate steadily. |
|
| * If [UP] appears, turn the pulley by hand to move the needle bar to |
|
| the needle up stop position, and then press the RESET key once |
|
| more. Home position detection will be carried out. |
|
| 0186B |
| ||
5 Repeat steps 3 and 4 to set the needle to the home position. | ||
6 Press the TEST key. | The [TEST] display and the [zigzag width/zigzag reference line | |
|
| position] indicator will switch off. |
|
| The setting will be written to the machine head memory and |
|
| adjustment mode will be exited. |
|
| 0183B |
NOTE:
If the TEST key is pressed while [orG] is flashing, [Err 202] will appear.
Press the TEST key once more to exit adjustment mode. Repeat the procedure from step 3.
22 |