MODEL NUMBER NOMENCLATURE — 542J150,180 UNITS

542J E X 150 000 AB H B

542J – High-Efficiency Rooftop Units

Electric Heat Pumps

Voltage Designation

E – 460-3-60

P – 208/230-3-60

T – 575-3-60

Heat Type

X – No Heat Installed

Nominal Cooling Capacity

150 – 12 Tons

180 – 15 Tons

Electric Heaters

 

000 – No Factory-Installed Electric Heaters

 

Accessory Field-Installed Electric Heaters

a50-8040

Available

 

Quality Assurance

Certified to ISO 9001:2000

ARI* CAPACITY RATINGS

548F036-060

Fan Drive Position

(Standard Motor)

B – Standard Low-Medium

Fan Drive Static Capability

D – Alternate High Fan

Drive Static Capability

Factory-Installed Outdoor Air Upgrade Options

C – Economizer

H – 25% Manual Damper

Design Series Code

AB – Economizer Design Change

 

 

 

COOLING

 

 

HEATING

 

 

UNIT

NOMINAL

 

 

 

(High Temp)

 

SOUND

 

 

 

 

 

 

548F

TONS

Net Capacity

 

 

SEER†

Capacity

 

 

RATING

 

 

 

 

 

HSPF

(decibels)

 

 

(Btuh)

 

Belt

 

Direct

(Btuh)

 

 

 

 

Drive

 

Drive

 

 

 

 

 

 

 

 

 

 

 

 

036

3

35,600

 

10.20

 

10.00

34,400

 

6.7

84

048

4

46,500

 

10.00

 

9.70

46,500

 

7.0

80

060

5

57,000

 

10.00

 

9.90

57,000

 

7.5

82

548F072-120

 

 

COOLING

 

HEATING

 

HEATING

 

 

SOUND

UNIT

NOMINAL

 

(High)

 

(Low)

 

 

 

 

 

 

IPLV**

RATING

548F

TONS

 

 

 

 

 

 

 

 

Net Capacity

EER

Capacity

 

COP

Capacity

 

COP

 

(decibels)

 

 

(Btuh)

(Btuh)

 

(Btuh)

 

 

 

 

 

 

 

 

 

 

 

072

6

70,000

9.05

72,400

 

3.20

42,000

 

2.14

82

090

71/2

86,000

9.00

78,000

 

3.00

39,000

 

1.80

9.3

86

120

10

112,000

9.00

105,000

 

3.10

59,000

 

2.00

9.0

84

 

LEGEND

COP

Coefficient of Performance

db

dry bulb

EER

Energy Efficiency Ratio

HSPF — Heating Seasonal Performance Factor

IPLV

Integrated Part-Load Values

SEER — Seasonal Energy Efficiency Ratio

wb

wet bulb

*Air Conditioning and Refrigeration Institute.

†Applies only to units with capacity of 60,000 Btuh or less. **The IPLV applies only to 2-stage cooling heat pump units.

NOTES:

1.Rated in accordance with ARI Standards 210/240-95 and 270-95.

2.Ratings are net values, reflecting the effects of circulating fan heat.

3.ALL the 548F036-060 units are in compliance with ASHRAE 90.1 2001 Energy Standard for minimum SEER and EER requirements. Refer to state and local codes or visit the following website: http://solstice.crest.org/efficiency/bcap to determine if compliance with this standard pertains to a given geographical area of the United States.

4. Ratings are based on:

Cooling Standard: 80 F db, 67 F wb indoor entering-air temperature and 95 F db air entering outdoor unit.

IPLV Standard: 80 F db, 67 F wb indoor entering-air temperature and 80 F db outdoor entering-air temperature.

High-Temp Heating Standard: 70 F db indoor entering-air temperature and 47 F db, 43 F wb outdoor entering-air temperature.

Low-Temp Heating Standard: 70 F db indoor entering-air temperature and 17 F db, 15 F wb outdoor entering-air temperature.

5

Page 5
Image 5
Bryant 549C manual Model Number Nomenclature 542J150,180 Units, ARI* Capacity Ratings, 548F036-060, 548F072-120