Bryant 549C manual OPTIONS AND ACCESSORIES cont

Models: 549C

1 170
Download 170 pages 54.16 Kb
Page 10
Image 10

OPTIONS AND ACCESSORIES (cont)

Roof Curbs (Horizontal and Vertical) permit installation and securing of ductwork to curb prior to mounting unit on the curb. Both 14-in. and 24-in. roof curbs are available as field-installed accessories.

EconoMi$erIV is available as a factory-installed option in vertical supply/return configuration only for unit sizes 036-120. Vertical or horizontal configuration is available for unit sizes 150 and 180. (EconoMi$erIV is available as a field-installed acces- sory for horizontal and/or vertical supply return configurations.) The EconoMi$erIV is provided with an industry standard, standalone, solid-state controller that is easy to configure and troubleshoot. The EconoMi$erIV is compatible with non-DDC applications. EconoMi$erIV is equipped with a barometric relief damper capable of relieving up to 100% return air. Dry bulb outdoor-air temperature sensor is provided as standard. The return air sensor, indoor enthalpy sensor, and outdoor enthalpy sensor are provided as field-installed accessories to provide enthalpy control, differential enthalpy control, and differential dry bulb temperature control.

EconoMi$er2 is available as a factory-installed option in verti- cal supply/return configuration only. (EconoMi$er2 is available as a field-installed accessory for horizontal and/or vertical supply return configurations.) The EconoMi$er2 is provided without a controller for use with field-installed third-party con- trols. EconoMi$er2 is equipped with a barometric relief damper capable of relieving up to 100% return air. Dry bulb outdoor-air temperature sensor is provided as standard. The enthalpy, differential temperature (adjustable), and differential enthalpy control are provided as field-installed accessories. The EconoMi$er2 is capable of control from a 4 to 20 mA signal through optional 4 to 20 mA design without microprocessor control (required for third party control interface).

Manual Outdoor-Air Damper accessory can be preset to admit up to 50% outdoor air for year round ventilation.

Two-Position Damper package is available as an accessory. Both 25% or 100% outdoor air dampers are available.

Head Pressure Control (Motormaster) accessory package maintains condensing temperature between 90 F and 110 F at outdoor ambient temperatures down to –20 F by condenser-fan speed modulation or condenser-fan cycling and wind baffles.

Electric Resistance Heaters are UL listed and available to match heating requirements. Single point kits available for each heater when required. Heaters are field-installed accessories.

Unit-Mounted, Non-Fused Disconnect Switch provides unit power shutoff. The switch is accessible from outside the unit and provides power off lockout capability and is available as factory-installed option.

Convenience Outlet is factory-installed and internally mounted with easily accessible 115-v female receptacle.

Compressor Cycle Delay (Time Guard II) prevents unit from restarting for minimum of 5 minutes after shutdown.

Thru-the-Bottom Utility Connectors permit electrical connec- tions to be brought to the unit through the basepan. Connectors are a field-installed accessory.

Fan/Filter Status Switch accessory provides status of indoor (evaporator) fan (ON/ OFF) or filter (CLEAN/DIRTY).

Power Exhaust accessory will provide system exhaust of up to 100% of return air (vertical only). The power exhaust is a field- installed accessory (separate vertical and horizontal design).

Ultra-Violet Germicidal Lamps eliminate odor causing mold and fungus that may develop in the wet area of the evaporator section of the unit. The high output, low temperature germicidal lamps are field installed in the evaporator section of the unit, aimed at the evaporator coil and condensate pan.

Hinged Panel Option provides hinged access panels for the fil- ter, compressor, evaporator fan, and control box areas. Filter hinged panels permit tool-less entry for changing filters. Each hinged panel is permanently attached to the rooftop unit and is a factory-installed option.

Emergency Heat Control Package accessory activates auxil- iary heat when necessary if mechanical heating is locked out.