FAN RPM AT MOTOR PULLEY SETTINGS* — 548F036-120

PERFORMANCE DATA — 548F (cont)

FAN RPM AT MOTOR PULLEY SETTINGS* — 548F036-120

 

 

 

UNIT

 

 

 

 

 

MOTOR PULLEY TURNS OPEN

 

 

 

 

 

 

 

 

548F

0

1/2

1

11/2

2

 

21/2

3

31/2

 

4

41/2

5

51/2

6

 

 

 

036†

1000

976

952

928

904

 

880

856

832

 

808

784

760

 

 

 

036**

1455

1423

1392

1360

1328

 

1297

1265

1233

 

1202

1170

1138

1107

1075

 

 

 

048†

1175

1135

1094

1054

1013

 

973

932

892

 

851

811

770

 

 

 

048**

1455

1423

1392

1360

1328

 

1297

1265

1233

 

1202

1170

1138

1107

1075

 

 

 

060†

1192

1166

1140

1114

1087

 

1061

1035

1009

 

983

957

930

904

878

 

 

 

060**

1685

1647

1608

1570

1531

 

1493

1454

1416

 

1377

1339

1300

 

 

 

072††

1460

1420

1380

1345

1305

 

1265

1225

1185

 

1150

1110

1070

548F

 

 

072**

1685

1647

1608

1570

1531

 

1493

1454

1416

 

1377

1339

1300

 

090††

840

815

790

765

740

 

715

690

665

 

635

615

590

 

 

 

 

 

 

 

 

090***

935

910

885

860

835

 

810

785

760

 

735

710

685

 

 

 

090**

1080

1025

1007

988

970

 

952

933

915

 

897

878

860

 

 

 

120††

935

910

885

860

835

 

810

785

760

 

735

710

685

 

 

 

120†

1085

1060

1035

1010

985

 

960

935

910

 

885

860

835

 

 

 

 

 

 

 

 

120**

1130

1112

1087

1062

1037

 

1012

987

962

 

937

912

887

862

830

*Approximate fan rpm shown.

†Indicates alternate motor and drive package. **Indicates high-static motor and drive package.

††Indicates standard motor and drive package.

***Indicates alternate drive package only.

ACCESSORY/HEATER STATIC PRESSURE* (in. wg) — 548F036-072

COMPONENT

 

 

 

 

 

 

 

 

 

 

 

CFM

 

 

 

 

 

 

 

900

 

1200

 

1400

 

1600

 

1800

 

2000

 

 

2200

 

2400

 

2600

3000

 

 

 

 

 

 

 

 

 

 

 

1 Heater Module

 

0.05

 

0.07

 

0.09

 

0.09

 

0.10

 

0.11

 

 

0.11

 

0.12

 

0.13

0.15

2 Heater Modules

 

0.15

 

0.16

 

0.16

 

0.16

 

0.17

 

0.17

 

 

0.17

 

0.18

 

0.18

0.19

*The static pressure must be added to external static pressure. The sum and the evaporator

 

 

 

 

 

 

entering-air cfm should then be used in conjunction with the Fan Performance tables to deter-

 

 

 

 

 

 

mine blower rpm and watts.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ACCESSORY/HEATER STATIC PRESSURE* (in. wg) — 548F090-120

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COMPONENT

 

 

 

 

 

 

 

 

 

 

 

CFM

 

 

 

 

 

 

 

2250

 

2500

 

3000

 

3500

 

4000

 

4500

 

 

5000

 

5500

 

6000

6250

 

 

 

 

 

 

 

 

 

 

 

1 Heater Module

 

0.02

 

0.03

 

0.05

 

0.07

 

0.08

 

0.10

 

 

0.12

 

0.14

 

0.16

0.17

2 Heater Modules

 

0.03

 

0.05

 

0.07

 

0.09

 

0.12

 

0.14

 

 

0.16

 

0.19

 

0.21

0.20

*The static pressure must be added to external static pressure. The sum and the evaporator

 

 

 

 

 

 

entering-air cfm should then be used in conjunction with the Fan Performance tables to deter-

 

 

 

 

 

 

mine blower rpm and watts.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ACCESSORY/FIOP STATIC PRESSURE* (in wg) — 548F036-072

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COMPONENT

 

 

 

 

 

 

 

 

 

 

CFM

 

 

 

 

 

 

 

 

 

1250

 

1500

 

1750

2000

 

 

2250

 

2500

 

2750

3000

 

 

 

 

 

 

 

 

 

 

 

 

Vertical EconoMi$erIV and EconoMi$er2

 

0.045

 

0.065

 

0.08

0.12

 

 

0.145

 

0.175

 

0.22

0.255

Horizontal EconoMi$erIV and EconoMi$er2

 

 

 

 

0.1

0.125

 

 

0.15

 

0.18

 

0.225

0.275

LEGEND

FIOP — Factory-Installed Option

*The static pressure must be added to external static pressure. The sum and the evaporator entering-air cfm should then be used in con- junction with the Fan Performance tables to determine blower rpm and watts.

ACCESSORY/FIOP STATIC PRESSURE* (in wg) — 548F090-120

COMPONENT

 

 

 

 

 

 

CFM

 

 

 

 

 

 

2250

2500

2750

3000

3250

3500

3750

4000

4250

4500

4750

5000

5250

6250

 

Vertical EconoMi$erIV and EconoMi$er2

0.06

0.075

0.09

0.115

0.13

0.15

0.17

0.195

0.22

0.25

0.285

0.325

0.36

Horizontal EconoMi$erIV and EconoMi$er2

0.1

0.125

0.15

0.18

0.21

0.25

0.275

0.3

0.34

0.388

LEGEND

FIOP — Factory-Installed Option

*The static pressure must be added to external static pressure. The sum and the evaporator entering-air cfm should then be used in con- junction with the Fan Performance tables to determine blower rpm and watts.