Bryant 549C manual PERFORMANCE DATA — 542J cont, FAN PERFORMANCE — VERTICAL DISCHARGE UNITS cont

Models: 549C

1 170
Download 170 pages 54.16 Kb
Page 149
Image 149
542J180 (15 TONS)*

PERFORMANCE DATA — 542J (cont)

FAN PERFORMANCE — VERTICAL DISCHARGE UNITS (cont)

542J180 (15 TONS)*

Airflow

 

 

 

 

 

 

 

 

 

 

 

External Static Pressure (in. wg)

 

 

 

 

 

 

 

 

0.2

 

 

 

 

0.4

 

 

 

 

0.6

 

 

 

 

0.8

 

 

 

1.0

 

(Cfm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rpm

 

Watts

 

Bhp

 

Rpm

 

Watts

 

Bhp

 

Rpm

 

Watts

 

Bhp

 

Rpm

Watts

 

Bhp

Rpm

Watts

Bhp

 

 

 

 

 

 

 

 

 

 

 

 

4500

584

717

0.8

695

952

1.1

798

1205

1.3

893

1483

1.7

984

1786

2.0

4800

609

839

0.9

717

1085

1.2

815

1346

1.5

907

1630

1.8

994

1938

2.2

5100

634

971

1.1

738

1229

1.4

833

1500

1.7

921

1791

2.0

1006

2104

2.4

5400

660

1118

1.3

760

1389

1.6

852

1669

1.9

937

1968

2.2

1019

2286

2.6

5700

687

1284

1.4

783

1566

1.8

873

1858

2.1

956

2165

2.4

1034

2490

2.8

6000

712

1458

1.6

805

1752

2.0

892

2055

2.3

973

2371

2.7

1049

2703

3.0

6300

736

1644

1.8

826

1952

2.2

911

2265

2.5

990

2591

2.9

1064

2930

3.3

6600

763

1856

2.1

851

2176

2.4

933

2502

2.8

1010

2837

3.2

1082

3186

3.6

6900

788

2078

2.3

873

2410

2.7

954

2747

3.1

1029

3093

3.5

1099

3451

3.9

7200

813

2316

2.6

896

2662

3.0

975

3011

3.4

1048

3367

3.8

1117

3734

4.2

7500

841

2584

2.9

921

2943

3.3

998

3304

3.7

1070

3672

4.1

1137

4049

4.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

542J180 (15 TONS)* (cont)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Airflow

 

 

 

 

 

 

 

 

 

 

 

External Static Pressure (in. wg)

 

 

 

 

 

 

 

 

1.2

 

 

 

 

1.4

 

 

 

 

1.6

 

 

 

 

1.8

 

 

 

2.0

 

(Cfm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rpm

 

Watts

 

Bhp

 

Rpm

 

Watts

 

Bhp

 

Rpm

 

Watts

 

Bhp

 

Rpm

Watts

 

Bhp

Rpm

Watts

Bhp

 

 

 

 

 

 

 

 

 

 

 

 

4500

 

1070

 

2113

 

2.4

 

1151

 

2458

 

2.8

 

1229

 

2819

 

3.2

 

1302

3194

 

3.6

4800

 

1078

 

2269

 

2.5

 

1157

 

2620

 

2.9

 

1233

 

2990

 

3.3

 

1306

3374

 

3.8

5100

 

1086

 

2439

 

2.7

 

1164

 

2795

 

3.1

 

1238

 

3170

 

3.5

 

 

5400

 

1097

 

2626

 

2.9

 

1172

 

2986

 

3.3

 

1245

 

3366

 

3.8

 

 

5700

 

1110

 

2835

 

3.2

 

1183

 

3200

 

3.6

 

1253

 

3584

 

4.0

 

 

6000

 

1122

 

3053

 

3.4

 

1193

 

3422

 

3.8

 

1262

 

3810

 

4.3

 

 

6300

 

1135

 

3286

 

3.7

 

1204

 

3660

 

4.1

 

1271

 

4052

 

4.5

 

 

6600

 

1151

 

3549

 

4.0

 

1218

 

3928

 

4.4

 

1283

 

4325

 

4.8

 

 

6900

 

1167

 

3821

 

4.3

 

1232

 

4207

 

4.7

 

1295

 

4608

 

5.2

 

 

7200

 

1183

 

4113

 

4.6

 

1246

 

4505

 

5.0

 

 

 

 

 

7500

 

1202

 

4437

 

5.0

 

1264

 

4837

 

5.4

 

 

 

 

 

LEGEND

Bhp — Brake Horsepower Input to Fan Watts — Input Watts to Motor

*Standard drive range is 817 to 1038 rpm. Alternate drive range is 1082 to 1303. Other rpms may require a field-supplied drive.

NOTES:

1.Maximum continuous bhp is 5.90 and maximum continuous watts are 5180. Do not adjust motor rpm such that motor maximum bhp and/or watts is exceeded at the maximum operating cfm.

2.Fan performance is identical for horizontal discharge applications using horizontal adapter curb (CRRFCURB013A00).

3.See this page for General Fan Performance notes.

GENERAL NOTES FOR FAN PERFORMANCE TABLES

1.Extensive motor and electrical testing on these units ensures that the full range of the motor can be utilized with confidence. Using your fan motors up to the wattage ratings shown will not result in nuisance tripping or premature motor failure. Unit warranty will not be affected. For additional information on motor performance, refer to Indoor-Fan Motor Performance table on page 150.

2.Values include losses for filters, unit casing, and wet coils. See page 151 for accessory/FIOP static pressure information.

3.Use of a field-supplied motor may affect wire sizing. Contact your Bryant representative for details.

4.Interpolation is permissible. Do not extrapolate.

542J

149

Page 149
Image 149
Bryant 549C manual PERFORMANCE DATA — 542J cont, FAN PERFORMANCE — VERTICAL DISCHARGE UNITS cont, 542J180 15 TONS