Bryant PERFORMANCE DATA — 549B, 549C cont, INSTANTANEOUS AND INTEGRATED HEATING RATINGS cont

Models: 549C

1 170
Download 170 pages 54.16 Kb
Page 88
Image 88
549B060 (5 Tons)

PERFORMANCE DATA — 549B, 549C (cont)

INSTANTANEOUS AND INTEGRATED HEATING RATINGS (cont)

 

 

 

549B060 (5 Tons)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Return

Cfm

 

 

 

 

 

 

Temperature Air Entering Outdoor Coil (F db at 70% rh)

 

 

 

 

 

 

 

 

Air

(Standard

–20

–10

 

0

10

17

30

40

47

50

60

 

 

 

(F db)

Air)

 

 

 

 

 

1500

Cap.

15.6

14.3

20.5

18.8

25.6

 

21.8

35.4

32.3

35.4

32.3

43.6

38.2

50.7

50.7

56.2

56.2

63.3

63.3

63.0

63.0

 

 

 

 

kW

3.16

3.26

3.36

3.54

3.54

3.72

3.88

4.01

4.20

4.18

 

 

 

 

 

 

 

 

 

1750

Cap.

16.0

14.7

20.9

19.2

26.0

 

22.1

35.8

32.7

35.8

32.7

44.6

39.1

51.3

51.3

56.4

56.4

62.9

62.9

63.0

63.0

 

 

 

55

kW

3.19

3.28

3.36

3.52

3.52

3.67

3.80

3.90

4.04

4.04

 

 

 

 

 

 

 

2000

Cap.

16.9

15.6

21.9

20.2

27.0

 

23.0

36.9

33.7

36.9

33.7

45.6

40.1

52.3

52.3

56.7

56.7

62.8

62.8

62.6

62.6

 

 

 

 

 

 

 

 

 

kW

3.41

3.49

3.56

3.69

3.69

3.83

3.93

4.01

4.12

4.11

 

 

 

 

 

 

 

 

 

2500

Cap.

18.9

17.6

23.9

22.1

29.1

 

25.0

38.9

35.7

38.9

35.7

47.8

42.1

53.5

53.5

56.9

56.9

62.2

62.2

62.5

62.5

 

 

 

 

kW

3.92

3.99

4.04

4.15

4.15

4.25

4.32

4.37

4.45

4.45

 

 

 

 

 

 

 

 

 

1500

Cap.

12.5

11.5

17.9

16.5

23.4

 

19.9

33.2

30.2

33.2

30.2

41.7

36.5

48.8

48.8

54.2

54.2

62.7

62.7

62.7

62.7

 

 

 

 

kW

3.46

3.63

3.78

4.01

4.01

4.23

4.44

4.60

4.86

4.85

 

 

 

 

 

 

 

 

 

1750

Cap.

13.0

11.9

18.4

16.9

23.9

 

20.3

33.8

30.8

33.8

30.8

42.3

37.1

49.5

49.5

55.0

55.0

62.1

62.1

63.1

63.1

 

 

 

70

kW

3.5

3.65

3.78

3.98

3.98

4.17

4.34

4.48

4.66

4.68

 

 

 

 

 

 

 

2000

Cap.

13.9

12.9

19.4

17.9

24.9

 

21.3

34.9

31.8

34.9

31.8

43.5

38.2

50.6

50.6

56.2

56.2

63.0

63.0

63.2

63.2

 

 

 

 

 

 

 

 

 

kW

3.73

3.87

3.98

4.15

4.15

4.32

4.47

4.58

4.73

4.73

 

 

 

 

 

 

 

 

 

2500

Cap.

16.0

14.9

21.5

19.9

27.0

 

23.3

37.1

34.0

37.1

34.0

45.8

40.4

52.9

52.9

57.7

57.7

63.3

63.3

63.1

63.1

 

 

 

 

kW

4.24

4.37

4.46

4.60

4.60

4.74

4.85

4.92

5.03

5.01

 

 

 

 

 

 

 

 

 

1500

Cap.

9.93

9.14

15.7

14.5

21.5

 

18.2

31.6

28.8

31.6

28.8

39.9

35.0

46.9

46.9

52.8

52.8

61.9

61.9

62.1

62.1

 

 

 

 

kW

3.65

3.87

4.06

4.36

4.36

4.59

4.82

5.02

5.35

5.35

 

 

 

 

 

 

 

 

 

1750

Cap.

10.3

9.51

16.2

14.9

22.0

 

18.7

32.2

29.4

32.2

29.4

40.7

35.7

47.7

47.7

53.6

53.6

62.1

62.1

62.5

62.5

 

 

 

80

kW

3.70

3.90

4.07

4.33

4.33

4.53

4.73

4.89

5.14

5.14

 

 

 

 

 

 

 

2000

Cap.

11.3

10.5

17.2

15.9

23.1

 

19.7

33.3

30.4

33.3

30.4

42.1

37.0

49.0

49.0

54.9

54.9

63.0

63.0

62.7

62.7

 

 

 

 

 

 

 

 

 

kW

3.92

4.11

4.27

4.50

4.50

4.67

4.85

4.99

5.19

5.18

 

 

 

 

 

 

 

 

 

2500

Cap.

13.4

12.5

19.4

18.0

25.3

 

21.8

35.6

32.6

35.6

32.6

44.4

39.2

51.7

51.7

57.0

57.0

63.8

63.8

63.8

63.8

 

 

 

 

kW

4.45

4.62

4.75

4.94

4.94

5.09

5.23

5.32

5.46

5.45

 

 

 

 

 

 

 

 

 

549C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

549B072 (6 Tons)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

549B,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(F db)

Air)

–20

–10

 

0

10

17

30

40

47

50

60

 

 

 

Return

Cfm

 

 

 

 

 

 

Temperature Air Entering Outdoor Coil (F db at 70% rh)

 

 

 

 

 

 

 

 

Air

(Standard

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1800

Cap.

16.5

15.2

20.8

19.1

26.4

 

22.4

33.6

30.8

41.0

37.6

51.3

44.9

61.9

61.9

69.5

69.5

78.0

78.0

77.9

77.9

 

 

 

 

kW

3.50

3.63

3.79

4.01

4.18

4.57

4.94

5.22

5.57

5.55

 

 

 

 

 

 

 

 

 

2100

Cap.

16.9

15.5

21.2

19.5

27.2

 

23.1

34.9

32.0

41.8

38.3

52.2

45.8

63.2

63.2

69.6

69.6

75.7

75.7

76.5

76.5

 

 

 

55

kW

3.56

3.68

3.84

4.04

4.18

4.54

4.86

5.07

5.30

5.32

 

 

 

 

 

 

 

2400

Cap.

17.2

15.9

21.8

20.0

28.0

 

23.8

35.6

32.6

43.1

39.5

53.8

47.2

64.1

64.1

69.0

69.0

74.8

74.8

74.3

74.3

 

 

 

 

 

 

 

 

 

kW

3.64

3.75

3.89

4.08

4.21

4.54

4.82

4.97

5.18

5.15

 

 

 

 

 

 

 

 

 

3000

Cap.

18

16.5

23.0

21.1

29.4

 

25.0

37.4

34.4

45.2

41.4

56.6

49.6

63.2

63.2

65.5

65.5

69.8

69.8

70.6

70.6

 

 

 

 

kW

3.79

3.90

4.03

4.19

4.32

4.61

4.77

4.84

4.98

4.99

 

 

 

 

 

 

 

 

 

1800

Cap.

15.2

14.0

18.2

16.7

24.1

 

20.5

31.1

28.5

38.0

34.8

47.7

41.8

58.4

58.4

67.1

67.1

78.0

78.0

77.9

77.9

 

 

 

 

kW

3.97

4.12

4.33

4.57

4.75

5.19

5.59

5.94

6.43

6.41

 

 

 

 

 

 

 

 

 

2100

Cap.

15.6

14.4

18.6

17.1

24.8

 

21.1

32.0

29.4

39.1

35.9

49.1

43.1

59.7

59.7

68.5

68.5

77.3

77.3

76.7

76.7

 

 

 

70

kW

4.04

4.18

4.37

4.59

4.76

5.15

5.51

5.81

6.17

6.13

 

 

 

 

 

 

 

2400

Cap.

16.1

14.8

19.0

17.5

25.9

 

22.0

32.7

30.0

39.9

36.6

51.1

44.7

61.3

61.3

69.0

69.0

75.6

75.6

76.3

76.3

 

 

 

 

 

 

 

 

 

kW

4.11

4.24

4.43

4.63

4.79

5.17

5.48

5.73

5.97

5.99

 

 

 

 

 

 

 

 

 

3000

Cap.

16.8

15.5

19.7

18.1

26.7

 

22.7

34.3

31.5

41.8

38.3

53.5

46.8

63.7

63.7

68.3

68.3

73.0

73.0

73.8

73.8

 

 

 

 

kW

4.28

4.39

4.56

4.75

4.89

5.22

5.49

5.63

5.80

5.82

 

 

 

 

 

 

 

 

 

1800

Cap.

13.6

12.5

17.1

15.7

21.7

 

18.4

29.2

26.8

36.5

33.4

45.6

40.0

55.3

55.3

64.2

64.2

77.2

77.2

76.9

76.9

 

 

 

 

kW

4.20

4.46

4.67

4.95

5.16

5.62

6.02

6.40

7.00

6.98

 

 

 

 

 

 

 

 

 

2100

Cap.

14.1

13.0

17.6

16.2

22.6

 

19.2

30.1

27.6

37.1

34.0

46.9

41.1

57.0

57.0

66.4

66.4

76.3

76.3

77.2

77.2

 

 

 

80

kW

4.28

4.52

4.72

4.98

5.16

5.58

5.95

6.30

6.71

6.74

 

 

 

 

 

 

 

2400

Cap.

14.5

13.4

18.0

16.6

23.1

 

19.6

31.2

28.7

37.9

32.7

48.5

42.5

58.7

58.7

67.7

67.7

76.3

76.3

75.9

75.9

 

 

 

 

 

 

 

 

 

kW

4.37

4.59

4.77

5.03

5.19

5.59

5.93

6.23

6.57

6.54

 

 

 

 

 

 

 

 

 

3000

Cap.

15.4

14.1

18.8

17.3

24.1

 

20.5

32.2

29.6

39.6

36.3

50.4

44.2

61.6

61.6

68.9

68.9

74.3

74.3

74.5

74.5

 

 

 

 

kW

4.54

4.74

4.91

5.14

5.29

5.64

5.95

6.17

6.37

6.36

 

 

 

 

 

LEGEND

Cap. — Heating Capacity (1000 Btuh) (includes indoor-fan motor heat) kW — Total Power Input (includes compressor motor power input,

outdoor-fan motor input, and indoor-fan motor input) rh — Relative Humidity

NOTES:

1.Manual background indicates integrated ratings.

2.Integrated capacity is maximum (instantaneous) capacity less the effect of frost on the outdoor coil and the heat required to defrost it.

88

Page 88
Image 88
Bryant manual PERFORMANCE DATA — 549B, 549C cont, INSTANTANEOUS AND INTEGRATED HEATING RATINGS cont, 549B060 5 Tons