PERFORMANCE DATA — 549B, 549C (cont)

INSTANTANEOUS AND INTEGRATED HEATING RATINGS (cont)

 

 

 

549B120 (10 Tons)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Return

Cfm

 

 

 

 

 

 

 

Temperature Air Entering Outdoor Coil (F db at 70% rh)

 

 

 

 

 

 

 

Air

(Standard

–20

–10

 

0

10

17

 

30

 

40

47

50

60

 

 

 

(F db)

Air)

 

 

 

 

 

 

 

3000

Cap.

37.7

34.6

45.5

41.9

53.5

 

49.2

62.6

57.5

69.2

63.1

84.3

74.0

101.3

 

101.3

111.3

 

111.3

116.0

116.0

134.2

134.2

 

 

 

 

kW

6.87

7.07

7.25

7.43

7.55

7.88

8.26

8.52

8.64

9.20

 

 

 

 

 

 

 

 

55

4000

Cap.

40.0

36.7

47.6

43.8

55.6

 

51.1

64.8

59.4

71.6

65.2

86.7

75.8

103.7

 

103.7

114.0

 

114.0

118.9

118.9

133.2

133.2

 

 

 

kW

7.45

7.63

7.78

7.93

8.05

8.33

8.67

8.92

9.05

9.40

 

 

 

 

5000

Cap.

42.2

38.6

49.7

45.9

57.7

 

53.0

66.9

61.2

73.7

67.4

88.8

77.7

105.9

 

105.9

116.2

 

116.2

119.9

119.9

131.0

131.0

 

 

 

 

kW

8.05

8.20

8.33

8.48

8.58

8.86

9.20

9.45

9.53

9.76

 

 

 

 

 

 

 

 

 

3000

Cap.

34.6

31.8

43.1

39.6

51.8

 

47.8

61.0

56.1

67.8

61.7

82.2

72.1

98.5

 

98.5

108.4

 

108.4

113.0

113.0

130.7

130.7

 

 

 

 

kW

7.45

7.75

8.03

8.28

8.45

8.86

9.28

9.55

9.71

10.29

 

 

 

 

 

 

 

 

70

4000

Cap.

36.7

33.9

45.5

41.7

54.2

 

49.9

63.1

57.9

69.9

63.8

84.3

74.0

101.0

 

101.0

110.8

 

110.8

115.8

115.8

133.4

133.4

 

 

 

kW

8.00

8.28

8.53

8.76

8.91

9.23

9.63

9.88

10.04

10.59

 

 

 

 

5000

Cap.

38.9

35.8

47.3

43.6

56.3

 

51.8

65.2

59.8

72.1

65.7

86.7

76.1

103.5

 

103.5

113.5

 

113.5

118.2

118.2

133.7

133.7

 

 

 

 

kW

8.58

8.86

9.06

9.28

9.41

9.73

10.11

10.37

10.49

10.92

 

 

 

 

 

 

 

 

 

3000

Cap.

31.6

29.0

40.7

37.4

50.2

 

46.2

59.6

54.9

66.7

60.8

80.8

70.7

96.8

 

96.8

06.4

 

106.4

111.1

111.1

128.0

128.0

 

 

 

 

kW

7.78

8.20

8.56

8.88

9.13

9.56

10.06

10.37

10.52

11.15

 

 

 

 

 

 

 

 

80

4000

Cap.

33.7

31.1

43.1

39.8

52.5

 

48.3

61.9

56.8

68.8

62.9

82.9

72.8

99.3

 

99.3

109.1

 

109.1

113.8

113.8

131.0

131.0

 

 

 

kW

8.33

8.73

9.06

9.33

9.53

9.93

10.37

10.64

10.80

11.38

 

 

 

 

5000

Cap.

35.8

33.0

45.5

41.7

54.6

 

50.4

64.1

58.6

70.9

64.8

85.3

74.7

101.5

 

101.5

111.6

 

111.6

116.2

116.2

133.4

133.4

 

 

 

 

kW

8.91

9.28

9.58

9.83

10.04

10.39

10.82

11.08

11.23

11.78

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

549C024 (2 Tons)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Return

Cfm

 

 

 

 

 

 

 

 

Temperature Air Entering Outdoor Coil (F db)

 

 

 

 

 

 

 

 

 

Air

(Standard

–20

–10

 

0

10

17

 

30

 

40

47

50

60

 

 

 

(F db)

Air)

 

 

 

 

 

 

 

600

Cap.

6.73

6.19

8.76

8.06

11

 

9.31

13.2

12.1

15.2

13.8

18.4

16.1

21.3

 

21.3

23.4

 

23.4

25.2

25.2

26.8

26.8

549C

 

 

 

kW

1.18

1.24

1.31

1.37

1.43

1.52

1.61

1.69

1.75

1.8

 

55

800

Cap.

6.96

6.4

8.99

8.27

11.2

 

9.56

13.4

12.3

15.4

14.1

18.7

16.4

21.6

 

21.6

23.9

 

23.9

25.2

25.2

26.6

26.6

kW

1.19

1.24

1.29

1.34

1.38

1.45

1.52

1.57

1.61

1.64

549B,

 

 

 

 

 

 

1000

Cap.

7.15

6.58

9.19

8.45

11.4

 

9.7

13.6

12.5

15.8

14.4

18.9

16.6

21.9

 

21.9

23.9

 

23.9

25

25

26.4

26.4

 

 

 

 

kW

1.21

1.26

1.3

1.33

1.37

1.42

1.48

1.52

1.54

1.57

 

 

 

 

 

 

 

 

 

600

Cap.

5.88

5.41

8.06

7.42

10.3

 

8.79

12.8

11.7

14.8

13.5

18

15.8

20.8

 

20.8

22.8

 

22.8

24.7

24.7

26.8

26.8

 

 

 

 

kW

1.34

1.43

1.52

1.61

1.68

1.8

 

1.91

1.99

2.07

2.16

 

 

 

70

800

Cap.

6.15

5.65

8.34

7.67

10.6

 

9.03

13.1

12

15.1

13.8

18.3

16

21.2

 

21.2

23.3

 

23.3

24.9

24.9

26.4

26.4

 

 

 

kW

1.36

1.43

1.5

1.57

1.62

1.71

1.79

1.86

1.91

1.95

 

 

 

 

 

 

 

 

 

1000

Cap.

6.35

5.84

8.56

7.88

10.9

 

9.22

13.3

12.2

15.3

13.9

18.5

16.2

21.4

 

21.4

23.6

 

23.6

24.9

24.9

26.5

26.5

 

 

 

 

kW

1.38

1.45

1.51

1.56

1.61

1.68

1.74

1.8

1.83

1.87

 

 

 

 

 

 

 

 

 

600

Cap.

5.11

4.7

7.46

6.86

9.83

 

8.36

12.3

11.3

14.4

13.1

17.8

15.6

20.5

 

20.5

22.5

 

22.5

24.4

24.4

26.5

26.5

 

 

 

 

kW

1.44

1.55

1.66

1.77

1.86

2

 

2.13

2.22

2.31

2.41

 

 

 

80

800

Cap.

5.39

4.96

7.76

7.13

10.2

 

8.64

12.7

11.6

14.7

13.4

18.1

15.9

20.9

 

20.9

22.9

 

22.9

24.6

24.6

26.6

26.6

 

 

 

kW

1.46

1.56

1.65

1.73

1.8

1.91

 

2

2.07

2.13

2.2

 

 

 

 

 

 

 

 

 

 

1000

Cap.

5.61

5.16

7.99

7.35

10.4

 

8.84

12.9

11.8

15

13.7

18.3

16

21.1

 

21.1

23.2

 

23.2

24.9

24.9

26.5

26.5

 

 

 

 

kW

1.48

1.58

1.65

1.73

1.78

1.86

1.94

 

2

2.04

2.09

 

 

 

 

 

 

LEGEND

Cap. — Heating Capacity (1000 Btuh) (includes indoor-fan motor heat) kW — Total Power Input (includes compressor motor power input,

outdoor-fan motor input, and indoor-fan motor input) rh — Relative Humidity

NOTES:

1. indicates integrated ratings.

2.Integrated capacity is maximum (instantaneous) capacity less the effect of frost on the outdoor coil and the heat required to defrost it.

90

Page 90
Image 90
Bryant 549C manual 549B120 10 Tons, 4000 Cap, 5000 Cap, 600 Cap, 800 Cap, 1000 Cap