DAMPER

ASSEMBLY

WIRE

HARNESS

DAMPER

WIRE TIES

ACTUATOR

 

 

PL7

ECONOMIZER BLOCK OFF

PL7

OUTSIDE AIR

ENTHALPY

INDOOR AIR

ENTHALPY

Fig. 23 — EconoMi$er IV Component Locations (Exploded View)

mA

MAT LOCATION

19

18

LED ON

 

 

 

D

 

 

 

17

 

 

 

 

 

 

 

16

LED OFF

LED ON

 

 

C

 

 

15

 

 

 

 

 

 

 

14

 

LED OFF

LED ON

 

13

 

 

B

 

 

 

 

 

12

 

 

LED OFF

LED ON

 

 

 

A

11

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OAT LOCATION

10

 

 

 

 

 

 

 

 

 

 

 

LED OFF

 

 

 

 

 

 

 

 

 

 

 

 

9

 

 

 

 

 

 

 

 

 

 

 

100

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40

45

50

55

60

65

70

75

80

85

90

95

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DEGREES FAHRENHEIT

 

 

 

 

 

 

Fig. 24 — Sensor Locations (OAT and MAT)

Fig. 25 — Temperature Changeover Set Points

 

 

 

 

 

 

 

 

 

Table 28 — EconoMi$er IV Sensor Usage

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ECONOMI$ER IV WITH OUTDOOR AIR

 

 

 

 

ECONOMI$ER IV WITH SINGLE

 

 

 

 

 

 

APPLICATION

 

 

DRY BULB SENSOR

 

 

 

 

 

ENTHALPY SENSOR

 

 

 

 

 

 

 

 

 

 

 

 

 

Accessories Required

 

 

 

 

 

Accessories Required

 

 

 

 

 

 

Outdoor Air Dry Bulb

 

None. The outdoor air dry bulb sensor is factory installed.

 

 

 

 

 

CRTEMPSN002A00*

 

 

 

 

 

 

Differential Dry Bulb

 

 

CRTEMPSN002A00*

 

 

 

 

 

(2) CRTEMPSN002A00*

 

 

 

 

 

 

 

Single Enthalpy

 

 

 

HH57AC078

 

 

None. The single enthalpy sensor is factory installed.

 

 

 

Differential Enthalpy

 

 

 

HH57AC078

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

and

 

 

 

 

 

 

CRENTDIF004A00*

 

 

 

 

 

 

 

 

 

 

 

 

 

CRENTDIF004A00*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CO2 for DCV Control using a

 

 

 

33ZCSENCO2

 

 

 

 

 

 

33ZCSENCO2

 

 

 

 

Wall-Mounted CO2 Sensor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CO2 for DCV Control using a

 

33ZCSENCO2†

 

OR

 

 

 

 

33ZCSENCO2†

 

 

OR

 

 

 

 

 

 

 

and

 

 

 

CRCBDIOX005A00††

 

 

 

and

 

 

 

 

CRCBDIOX005A00††

Duct-Mounted CO2 Sensor

 

 

 

 

 

 

 

 

 

 

 

 

33ZCASPCO2**

 

 

 

 

 

 

33ZCASPCO2**

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*CRENTDIF004A00 and CRTEMPSN002A00 accessories are used on many different base units. As such, these kits may contain parts that will not be needed for installation.

†33ZCSENCO2 is an accessory CO2 sensor.

**33ZCASPCO2 is an accessory aspirator box required for duct-mounted applications. ††CRCBDIOX005A00 is an accessory that contains both 33ZCSENCO2 and 33ZCASPCO2 accessories.

40

Page 40
Image 40
Carrier 48PG20-28 specifications EconoMi$er IV Sensor Usage