Cisco Systems AS5400XM quick start Verifying Channelized T3 Controller Operation

Models: AS5400XM

1 68
Download 68 pages 41.48 Kb
Page 44
Image 44
Verifying Channelized T3 Controller Operation

Step 1 Use the enable command and password to enter privileged EXEC mode. You are in privileged EXEC mode when the prompt changes to Gateway#.

Gateway> enable

Password: password

Gateway#

Step 2 Enter global configuration mode. You are in global configuration mode when the prompt changes to Gateway(config)#.

Gateway# configure terminal

Enter configuration commands, one per line. End with CNTL/Z.

Gateway(config)#

Step 3 Enter controller configuration mode to configure your T3 controller for slot 1 port 0. Slot values range from 1 to 7. The port number is always 0.

Gateway(config)# controller t3 1/0

Gateway(config-controller)#

Step 4 Enter the telco framing type, either c-bitor m23:

Gateway(config-controller)# framing c-bit

Step 5 Enter your clock source, either internal or line:

Gateway(config-controller)# clock source line

Step 6 Enter your cable length. Values range in feet from 0 to 450.

Gateway(config-controller)# cablelength 450

Step 7 Configure your T1 controllers. The range is 1 to 28.

To configure all 28 T1 controllers at once, enter:

Gateway(config-controller)# t1 1-28 controller

To omit specified T1 controllers while configuring others, specify them as needed. In this instance, T1 controllers 11–14, 21, 22, and 24–28 are not configured.

Gateway(config-controller)# t1 1-10,15-20,23 controller

Step 8 Return to privileged EXEC mode:

Gateway(config-controller)# Ctrl-Z

Gateway#

Tip To save the gateway configuration, save it to NVRAM. See the “Saving Configuration Changes” section on page 60.

Verifying Channelized T3 Controller Operation

To verify that your controller is up and running and that no alarms have been reported, enter the show controller command and specify the controller type, slot, and port numbers:

Gateway# show controller t3 1/0

T3 1/0 is up.

Applique type is Channelized T3

No alarms detected.

MDL transmission is disabled

FEAC code received:No code is being received

Framing is C-BIT Parity, Line Code is B3ZS, Clock Source is Internal Data in current interval (270 seconds elapsed):

0 Line Code Violations, 0 P-bit Coding Violation

44

Page 44
Image 44
Cisco Systems AS5400XM quick start Verifying Channelized T3 Controller Operation