last. Statement 197

Step 2 Note the orientation of the DC power supply. The power supply cord should have three wires: 48 VDC Return, –48 VDC, and a safety ground (green wire). (See Figure 38, Figure 39, and Figure 40.)

Warning

The illustration shows the DC power supply terminal block. Wire the DC power supply using the appropriate lugs

 

at the wiring end, or with no lugs, as illustrated. The proper wiring sequence is ground to ground, positive to

 

positive, and negative to negative. Note that the ground wire should always be connected first and disconnected

 

last. Statement 197

 

 

 

 

 

Figure 38 Cisco AS5350XM Universal Gateway DC Power Supply Connections—Single Power Supply

 

Power switch

 

To DC source

 

 

Power switchTo DC source DC connector

 

56022

Source A - NEG

Ground

Source A - RTN

Source B - RTN

Source B - NEG

29