40
Console logging: disabled
Monitor logging: level debugging, 0 messages logged, xml disabled,
filtering disabled
Buffer logging: level debugging, 81 messages logged, xml disabled,
filtering disabled
Exception Logging: size (4096 bytes)
Count and timestamp logging messages: disabled
Persistent logging: disabled
No active filter modules.
Trap logging: level informational, 78 message lines logged
Log Buffer (10000000 bytes):
*Jan 10 06:08:14.713: %CMRP-3-PEM_REMOVE_SHUT: R0/0: cmand: The system will shut down in 5 minutes
*Jan 10 06:08:14.718: %ASR1000_PEM-6-REMPEM_FM: PEM/FM slot P1 removed
*Jan 10 06:08:28.966: %ASR1000_PEM-6-INSPEM_FM: PEM/FM slot P1 inserted
The second is after enabling console logging. Output is at the console (and in the log).
6ru_perf2#conf Configuring from terminal, memory, or network [terminal]?
Enter configuration commands, one per line. End with CNTL/Z.
6ru_perf2(config)#log con
% Ambiguous command: "log con"
6ru_perf2(config)#logg con
6ru_perf2(config)#^Z
6ru_perf2#
*Jan 10 06:08:54.643: %SYS-5-CONFIG_I: Configured from console by console
6ru_perf2#
6ru_perf2# *Jan 10 06:09:05.023: %CMRP-3-PEM_REMOVE_SHUT: R0/0: cmand: The system will shut down in 5
minutes
*Jan 10 06:09:05.026: %ASR1000_PEM-6-REMPEM_FM: PEM/FM slot P0 removed
*Jan 10 06:09:10.500: %ASR1000_PEM-6-INSPEM_FM: PEM/FM slot P0 inserted
6ru_perf2#
Step10 Replace the DC power supply within five minutes or the system will shutdown.
This completes the procedure of removing a DC power supply from the Cisco ASR 1006 Router.

Replace the DC Power Supply

For instructions to replace the DC power supply in the Cisco ASR 1006 Router, go to Connect DC Power to the Cisco ASR 1006
Router, page 16.
Install and Remove the Shared Port Adapter
This section provides instructions for installing and removing a shared port adapter in a SIP Each SPA circuit board is mounted
to a metal carrier and is sensitive to electrostatic discharge (ESD) damage.
Caution Always handle the SPA by the carrier edges and handle; never touch the SPA components or connector pins. (See
Figure 19.)
When a subslot is not in use, a SPA blank filler plate must fill the empty subslot to allow the router or switch to conform to
electromagnetic interference (EMI) emissions requirements and to allow proper airflow across the SPAs. If you plan to install a
SPA in a subslot that is not in use, you must first remove the SPA blank filler plate.