CHECKING
REPEATABILITY
Before any Conair
Type of Cutter | Repeatability Time |
AC Pneumatic Cutter | Less than 1 millisecond |
DC Pneumatic Cutter | Less than 1.5 millisecond |
Positional Servo | Less than 0.1 millisecond |
Note:
The repeatability mode is built into the Conair cutter controls and allows you to perform similar tests, without any external test equipment. It is recommended that you check repeatability on a regular basis. Refer to Operation Section 4, Control Instructions Test to run repeatability tests. Acceleration/decel- eration delays of the servo do not contribute to repeatability error; any error is attributed solely to motor stability, cou- plings, assembly, power, and proximity sensor alignment.
Use any blade speed and line speed. The line speed is only seen while in the Encoder or Product modes. It is recommend- ed that the tests be performed at cut intervals between 0.5 and
| INSTALLATION | UGE059/1003 |