CONTROL

CONTROL

INSTRUCTIONS

SCALE COUNTS

COUNTS SOFTKEY

By pressing the soft key located under the word Counts on the Scale Value12.Scree000in,.theEQUALSscaled counts are available. Additional information on1200COUNTShow to access this screen can be found in the Maintenance Area of the operator display overview in Appendix E of th s manual.

The number shown is the current count value, i.e. the pulses per revolution of the encoder. For example a 3000 pulse quad- rature encoder will produce 3000 x 4 channels or 12000 counts. A cursor will appear in the least significant digit. The user has a choice of ways to adjust this number.

Exit or Prev, if no change is required press Exit or Prev to return to the Scale Value screen.

Raise will increase the value by 1. The key can be pressed once for each 1 increment required or held down to scroll up. Releasing the key will freeze the value at the last value.

Lower will decrease the value by 1. The key can be pressed once for each 1 decrement required or held down to scroll down. Releasing the key will freeze the value at the last value.

Numeric keys

Key in the count desired and press enter. If you require 12000 counts you must key in 12000 and then press enter.

Enter or Delete?

If the keyed in number is correct press the enter key for it to be accepted and return to the Scale Value screen. If it is wrong press the delete key and the previous value will reappear.

4-24