Conair SC-5 Weekly, Monthly, Semi-annual every 6 months, this option. See Cleaning the Blade Tray

Models: SC-5

1 121
Download 121 pages 35.17 Kb
Page 71
Image 71
●Weekly

Weekly

Cleaning the blade lubrication tray (if the cutter

has

this option). See Cleaning the Blade Tray,

Section 5.

 

Lubricating shafts on optional slide rail system See Cleaning the Blade Tray, Section 5.

PREVENTATIVE

MAINTENANCE

SCHEDULE

Monthly

CONTINUED

 

Checking hardware on the knife guard

Inspect the hardware on the knife guard (fasteners on hinge and the clear blade guard window). Tighten as needed.

Checking bushing holder proximity switches Inspect the sets screws which retain the bushing holder proximity switches for tightness. Adjust as needed. See Adjusting the Proximity Switches, Section 5.

Checking the draw latch

Inspect the latch on knife guard windows for wear and

Draw Latch

Clear Guard Windows

Clean the clear blade guard window

Clean using glass cleaner or plain water. Other materi- als may cause premature loss of clarity or crazing.

Semi-annual (every 6 months)

Inspecting electrical terminals

Check all electrical terminals for tightness; adjust as needed. See Checking Electrical Connections, Section 5.

Checking torque on Trantorque coupling device Check the tightness (torque) of the Trantorque coupling device with a torque gauge. This device connects the cutter head to the Micron reducer shaft. See Checking Torque, Section 5.

Checking all electrical cables

Inspect all electrical cables for cuts and abrasions.

Replace as needed.

Inspecting control panel lights

Check to make sure no LEDs or lights are burned out on the control panel. Replace as needed.

UGE059/1003

SC-5 SURE CUT Servo Knife Cutter

MAINTENANCE 5-5

Page 71
Image 71
Conair SC-5 manual Weekly, Monthly, Semi-annual every 6 months, Cleaning the blade lubrication tray if the cutter, Section