DISTANCE SOFTKEY
By pressing the soft key located under the word Dist. on the
Scale Value Screen, the scaled distance is available. This value
must be setCOUNTS12after a12U/M..0000in0chain..ge. Additional information on how to access this screen can be found in the Maintenance Area of the operator display overview in Appendix E of this manual.
ENTERDISTANCEPERPER
The number shown is the current distance value, i.e. the cir- cumference of the measuring wheel or distance per revolution of the encoder. A cursor will appear in the least significant digit.
Exit or Prev- if no change is required press Exit or Prev to return to the Scale Value screen.
Raise will increase the value by 0.001inch. The key can be pressed once for each 0.001inch increment required or held down to scroll up. Releasing the key will freeze the value at the last value.
Lower will decrease the value by 0.001inch. The key can be pressed once for each 0.001inch decrement required or held down to scroll down. Releasing the key will freeze the value at the last value.
Numeric keys
Key in the distance desired and press enter. The decimal place is fixed so remember this when entering the value. If you require 12.000 inches you must key in 12000 and then press enter. Keying only 12 will set the distance to 0.012 inches.
Enter or Delete?
If the keyed in number is correct press the enter key for it to be accepted and return to the Scale Value screen. If it is wrong press the delete key and the previous value will reappear.
CONTROL
INSTRUCTIONS
SCALE
DISTANCE
UGE059/1003 | OPERATION |