CONTROL
INSTRUCTIONS
ENCODER DIRECTION
CONTINUED
If a negative symbol is shown to the left of the count value on the main mode screen the encoder signal is reversed, i.e. rotat- ing in the wrong direction. The Cutter will not function while the encoder is going negative. The Direction function corrects this by changing what the servo drive interprets as a positive direction, CW or CCW rotation.
| CONTROL | UNIT OF MEASURE SOFTKEY |
| INSTRUCTIONS UNIT | By pressing the soft key located under the word U/M on the |
| Encoder Area screen, the Eng Units can be set. | |
| OF MEASURE | inSEL..UNITExitOFMEASUREmm. |
|
|
|
Exit or Prev, Pressing Exit or Prev will return the display to the Encoder Area screen.
in./mm. Softkeys
Pressing the soft key located under in. or mm. Changes all dis- played measurements to the respective unit of measure.
The scaled distance must now be set for the desired unit. See the Scale Area Dist. Softkey description.
Scale Softkey
By pressing the soft key located under the word Scale on the EncoderDistArea.SELECTScreen,ExitSCALEthereAREACountsare two
Exit or Prev, Pressing Exit or Prev will return the display to the Encoder Area screen.
SETTING THE SCALE FACTOR
The Encoder mode uses a scale factor to compensate for con- figurations that differ from the standard (a measuring wheel with a 1 foot circumference; a 3000
| OPERATION | UGE059/1003 |