cfgRemoteHosts
cfgSerial
cfgSessionManagement
For more information about the property default values and ranges, see the Chassis Management
Controller for PowerEdge VRTX RACADM Command Line Reference Guide available at dell.com/
support/manuals.
Configuring iDRAC Virtual LAN Tag Settings
Virtual LAN (VLAN) tags enable multiple VLANs to coexist on the same physical network cable and to
segregate the network traffic for security or load management purposes. When you enable the VLAN
functionality, each network packet is assigned a VLAN tag. VLAN tags are chassis properties. They remain
with the chassis even when a component is removed.

Configuring iDRAC Virtual LAN Tag Settings Using RACADM

Specify the Virtual LAN ID and priority of a particular server with the following command:
racadm setniccfg -m server-<n> -v <VLAN id> <VLAN priority>
The valid values for <n> are 1–4.
The valid values for <VLAN> are 1–4000 and 4021–4094. Default is 1.
The valid values for <VLAN priority> are 0–7. Default is 0.
For example:
racadm setniccfg -m server-1 -v 1 7
For example:
To remove a server VLAN, disable the VLAN capabilities of the specified server's network:
racadm setniccfg -m server-<n> -v
The valid values for <n> are 1–4.
For example:
racadm setniccfg -m server-1 -v

Configuring iDRAC Virtual LAN Tag Settings Using Web Interface

To configure Vitual LAN(VLAN) for server:
1. Go to any of the following pages:
In the left pane, click Chassis OverviewNetworkVLAN.
In the left pane, click Chassis OverviewServer Overview and click SetupVLAN.
2. On the VLAN Tag Settings page, in the iDRAC section, enable VLAN for the server(s), set the priority
and enter the ID. For more information about the fields, see the Online Help.
3. Click Apply to save the settings.
103