racdump includes the following subsystems and aggregates the following RACADM commands. For more information about racdump, see the RACADM Command Line Reference Guide for CMC in PowerEdge VRTX.

Subsystem

RACADM Command

 

 

General System/RAC information

getsysinfo

Session information

getssninfo

Sensor information

getsensorinfo

Switches information (IO Module)

getioinfo

Mezzanine card information (Daughter card)

getdcinfo

All modules information

getmodinfo

Power budget information

getpbinfo

KVM information

getkvminfo

NIC information (CMC module)

getniccfg

Redundancy information

getredundancymode

Trace log information

gettracelog

RAC event log

getraclog

System event log

getsel

Downloading SNMP Management Information Base (MIB) File

The CMC SNMP MIB file defines the chassis types, events, and indicators. CMC enables you to download the MIB file using the web interface.

To download the CMC's SNMP Management Information Base (MIB) file using the CMC web interface:

1.In the left pane, click Chassis Overview Network Services SNMP.

2.In the SNMP Configuration section, click Save to download the CMC MIB file to your local system.

For more information about the SNMP MIB file, see the Dell OpenManage Server Administrator SNMP Reference Guide at dell.com/support/manuals.

First Steps to Troubleshoot a Remote System

The following questions are commonly used to troubleshoot high-level issues in the managed system:

Is the system turned on or turned off?

If turned on, is the operating system functioning, not responding, or stopped functioning?

If turned off, did the power turn off unexpectedly?

Power Troubleshooting

The following information helps you to troubleshoot power supply and power-related issues:

Problem: Configured the Power Redundancy Policy to Grid Redundancy, and a Power Supply Redundancy Lost event was raised.

206