Power Cycle Server (cold boot)

For information about the options, see the Online Help.

3.Click Apply.

A dialog box appears requesting for confirmation.

4.Click OK to perform the power management action (for example, reset the server).

Executing Power Control Operations on the IOM

You can remotely reset or turn on an IOM.

NOTE: To perform power management actions, you must have the Chassis Configuration Administrator privilege.

Executing Power Control Operations on IOM Using CMC Web Interface

To execute power control operations on the I/O Module:

1.In the left pane, click Chassis Overview I/O Module Overview Power.

2.On the Power Control page, for the IOM, from the drop-down menu, select the operation you want to execute (power cycle).

3.Click Apply.

Executing Power Control Operations on the IOM Using RACADM

To execute power control operations on the IOM using RACADM, open a serial/Telnet/SSH text console to CMC, log in, and type:

racadm chassisaction -m switch <action>

where <action> indicates the operation you want to execute: power cycle.