To import or clear the foreign configuration:

1.In the left pane, click Chassis Overview Storage Controllers Setup.

2.On the Controller Setup page, in the Foreign Configuration section, for the respective controller, click:

Clear Foreign Configuration to clear the existing configuration of the disk.

Import/Recover to import the disk with the foreign configuration.

Configuring Storage Controller Settings

You can modify existing properties of a storage controller or configure the properties of a newly-installed storage controller.

Configuring Storage Controller Settings Using CMC Web Interface

Make sure at least one storage controller is installed in the chassis.

Toconfigure the storage controller settings:

1.In the CMC Web interface, go to Chassis Overview Storage Controllers Setup.

2.On the Controller Setup page, from the Controller drop-down menu, select the controller.

NOTE: Note the following:

If the storage controllers are in fault-tolerant mode, and if both have the same firmware version, then both the controllers are displayed as a single device in the drop-down menu. For example, Shared PERC8 (Integrated 1)/ Shared PERC8 (Integrated 2). If the settings of two controllers are different, the Settings Incompatible message is displayed. You can set the properties of fault-tolerant controllers so that the properties are same on both the controllers. Controllers in this mode cannot have separate properties.

If a second storage controller with a different firmware version is installed, then the controllers are displayed as two different components in the drop-down menu. For example, Shared PERC8 (Integrated 1) and Shared PERC8 (Integrated 2).

The attribute values for the selected controller are updated in the table.

3.Type or select appropriate data, and then click Apply.

NOTE: For information about the attributes and other field descriptions, see Online Help.

The newly set properties are applied to the selected controllers and the Current Value field displays the updated values for the attributes.

Configuring Storage Controller Settings Using RACADM

To set up the storage controller by running a RACADM command, use the following syntax.

racadm raid ctrlprop:RAID.ChassisIntegrated.1-1 [-rebuild <value>] [-bgi <value>] [-reconstruct <value>] [-checkconsistency <value>] [-ccmode {abortonerror normal}] [-copybackmode {off on onwithsmart}] [-lb {auto disabled}] [-prunconfigured {yes no}]

For more information, see the Chassis Management Controller for PowerEdge VRTX RACADM Command Line Reference Guide.