Exported Data

The server inventory report contains data that was most recently returned by each Chassis Group member during the Chassis Group leader’s normal polling (after every 30 seconds).

To get the most accurate server inventory report:

The Chassis Group leader chassis and all Chassis Group member chassis must be in Chassis Power State On.

All servers in the associated chassis must be turned on.

The inventory data for the associated chassis and servers may be missing in inventory report, if a subset of the Chassis Group member chassis are:

In Chassis Power State Off state

Turned off

NOTE: If a server is inserted while the chassis is turned off, the model number is not displayed anywhere in the web interface until the chassis is turned on again.

The following table lists the specific data fields and specific requirements for fields to be reported for each server:

Table 8. Server Module Inventory Field Descriptions

Data Field

Example

 

 

Chassis Name

Data Center Chassis Leader

Chassis IP Address

192.168.0.1

Slot Location

1

Slot Name

SLOT-01

Host Name

Corporate Webserver

 

NOTE: Requires a Server Administrator agent

 

running on the Server; otherwise shown as

 

blank.

Operating System

Windows Server 2008

 

NOTE: Requires a Server Administrator agent

 

running on the Server; otherwise shown as

 

blank.

Model

PowerEdgeM610

Service Tag

1PB8VF1

Total System Memory

4.0 GB

 

NOTE: Requires VRTX CMC 1.0 (or later) on

 

member; otherwise shown as blank.

# of CPUs

2