Table 3-1. System Messages (Continued)

Message

Cause

Action

 

 

 

Stepping of CPU2

A Pentium Pro micro-

Replace the microprocessor with a correct version of the Pen-

is less than sA1

processor that is not

tium Pro microprocessor from Dell. See “Upgrading the

- System halted!

supported by the system

Microprocessor or Installing a Secondary Microprocessor” in

 

is installed in the

Chapter 8 for details.

 

PROCESSOR2 socket.

 

 

 

 

Stepping of CPU

A Pentium Pro micro-

Replace the microprocessor with a correct version of the Pen-

is less than sA1

processor that is not

tium Pro microprocessor from Dell. See “Upgrading the

- System halted!

supported by the system

Microprocessor or Installing a Secondary Microprocessor” in

 

is installed.

Chapter 8 for details.

 

 

 

Nonidentical

The cache memory size

Replace one of the microprocessors so that the cache size of

CPUs - System

of the two Pentium Pro

the two microprocessors matches. See “Upgrading the Micro-

halted!

microprocessors must

processor or Installing a Secondary Microprocessor” in

 

match.

Chapter 8 for details.

 

 

 

Invalid CPU

The microprocessor

Check the microprocessor speed jumpers. See Table C-1.

speed detected -

speed detected is not

 

Check speed

180 MHz or 200 MHz.

 

jumpers. System

 

 

halted.

 

 

 

 

 

Power supply

The server-management

Check the server-management bus cable connections to the

paralleling

bus cable connection to

system board (labeled “SMB BACKPLANE”) and SCSI

board firmware

the SCSI backplane

backplane (labeled “SMB”).

download failed

board may be loose,

 

 

preventing the firmware

 

System back-

from downloading dur-

 

plane firmware

ing system start-up.

 

download failed

 

 

 

 

 

Embedded server

The embedded server

Turn off the system to clear the memory, then restart the sys-

management firm-

management memory

tem.

ware download

may be temporarily cor-

 

failed

rupted.

 