Table 1-4. System Messages (continued)

Message

Causes

Corrective Actions

 

 

 

Memory address line

Faulty or improperly installed memory

Ensure that all memory modules are

failure at address, read

modules, or faulty system board.

properly installed. See "Troubleshooting

value expecting value

 

System Memory" on page 88. If the

Memory double word logic

 

problem persists, see "Getting Help" on

 

page 103.

failure at address, read

 

 

 

value expecting value

 

 

Memory odd/even logic

 

 

failure at start address

 

 

to end address

 

 

Memory write/read failure

 

 

at address, read value

 

 

expecting value

 

 

 

 

 

Memory tests terminated by

The spacebar was pressed during

Information only.

keystroke

POST to terminate the memory test.

 

 

 

 

No boot device available

The system cannot find the diskette or

If the diskette drive is your boot device,

 

hard drive.

ensure that a bootable disk is in the

 

 

drive.

 

 

If the hard drive is your boot device,

 

 

ensure that the hard drive is installed,

 

 

properly seated, and partitioned as a

 

 

boot device.

 

 

Enter the System Setup program and

 

 

verify the boot sequence information.

 

 

See your Hardware Owner’s Manual for

 

 

details.

 

 

 

No boot sector on

The system configuration information

Enter the System Setup program and

hard-disk drive

in the System Setup program might

verify the system configuration

 

be incorrect.

information for the hard drive. See your

 

 

Hardware Owner’s Manual for details.

 

 

If the message continues to appear after

 

 

verifying the information in the System

 

 

Setup program, the operating system

 

 

might have been corrupted. Reinstall the

 

 

operating system. See your operating

 

 

system documentation for reinstallation

 

 

information.

 

 

 

No timer tick interrupt

A chip on the system board might be

Run the system diagnostics. See

 

malfunctioning.

"Running the System Diagnostics" on

 

 

page 93.

18

About Your System

Page 18
Image 18