Troubleshooting Your System 85
4
Let the system dry thoroughly for at least 24 hours.
5
Close the system. See "Closing the System" on page47.
6
Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.
If the system does not start properly, see "Getting Help" on page103.
7
If the system starts properly, shut down the system and reinstall all of the expansion cards that you
removed. See "Installing an Expansion Card" on page63.
8
Run the appropriate online diagnostic test. See "Using Dell PowerEdge Diagnostics" on page93.
If the tests fail, see "Getting Help" on page 103.
Troubleshooting a Damaged System
Problem
System was dropped or damaged.
Action
CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the
components inside the system. Before performing any procedure, see your Product Information Guide for
complete information about safety precautions, working inside the computer and protecting against electrostatic
discharge.
1
Open the system. See "Opening the System" on page 46.
2
Ensure that the following components are properly installed:
Expansion cards
Power supplies
•Fans
3
Ensure that all cables are properly connected.
4
Close the system. See "Closing the System" on page47.
5
Run the system board tests in the system diagnostics. See "Running the System Diagnostics" on
page93.
If the tests fail, see "Getting Help" on page 103.